Fire Alarm System, Control System, Fire Alarm manufacturer / supplier in China, offering Wired Addressable Control Panel Fire Alarm System, 2-Wire Conventional Fire Alarm Control Panel for Hotel Use, Asenware Manufacturer Addressable Fire Alarm Control Panel for Office Building and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $525.00/ Piece |
Local Area: | Shenzhen, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal, WesternUnion |
Type: | Industry Alarm |
---|---|
Signal Transmission: | Wired Alarm |
Working Mode: | Active |
ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panelModel No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32Power specification
Mains supply voltage110VAC or 240VACInternal power supply27.2VDCTotal output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VACMain supply monitor for faultYesBattery protection for low voltageYesBatteries (default configuration)12V2AH*2Detector circuit specification
Number of circuit124-164-32Line fault monitor for open circuitYesLine fault monitor for short circuitYesLine fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line ResistorEnd of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)Call point resistor value470 to 680 Ω, 0.225 or 0.5 wattMaximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.Maximum number of manual call points per zoneNo limitSounder circuit specification
Number of general circuits2End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)Line fault monitor for open circuitYesLine fault monitor for short circuitYesOutputs fused AT400mAMaximum number of bells @ 20mA of each sounder output20Fuses
Battery fuse1.5A F 20mmSounder outputs500mA F 20mmFire and fault output
Output typeNC and NO relayMaximum current100mAConnection block
Largest acceptable conductor size2.5mm2Smallest acceptable conductor size0.75mm2Size and weight
Dimensions(mm)272*200*70mm320*231*90mm395X502X124362X565X124Weight (without batteries)4kg5kg7kg8kgWeight (with batteries)5.8kg6.8kg9.6kg12.5kg
Our company
Asenware, manufacturer of fire alarm and fire suppression system since 2005. Our headquarter is in London, UK, with factory Shenzhen, China
We keep our best service for our customers, and have a rich experienced engineer team to design and install for overseas projects.
Product range:
1. Addressable fire alarm system(FP100 series,2189,2100 series)
2. Conventional fire alarm system(2166 series)
3. FM200 gas fire suppression system
4. Emergency light system
5. Fire pump system
6. Fire hose and fire hose reel cabinet
Welcome contact
mobile:0086-136-3251-2808