Business Type:
Trading Company
Business Range:
pH Meters, Counter Meters, Arbor Press, Tools, Ddvp
Establishment:
2004
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, PayPal, WesternUnion, Small-amountpayment
Main Markets:
North America, Southeast Asia, Middle East, East Asia(Japan, South Korea)
OEM/ODM Service
Sample Available

PH Meter, Physical Measuring Meter, pH Electrode manufacturer / supplier in China, offering High Sensitivity, Fast Response pH Meter (pH-009(III)), Underground Metal Detector with Gold Prospector, Professional Colorful WiFi APP Weather Station and so on.

1
    YRS
General Supplier

China Atomic Absorption Spectrophotometer

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Qingdao, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion, Small-amountpayment
Atomic Absorption Spectrophotometer (AAS) AMT3800 Serials
Features
1. Advance technologies intelligent stray light measure and correction technology
2. Automatic measurement and stray light dynamic detected without any reference materials and increment cost. It improved instrument's optical precision. Linear range and background correction effectively.
3. Original Optical Noise Reduction, it improved instrument's optical performance, linear range and enhanced background correction.
4. Developed interval lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability. Meanwhile it will prolonged working like of the lamp. The cost of normal hallow cathode lamp is only about 1/10 of special lamp.
4. Original "Hg lamp-reagent" gradient measurement. We established an exact mathematical model to estimate "double beam linear and balance" specification. This technology provided a fast and economic method for instrument self testing system. It also established a brand new method to improve instrument's detection performance.
5. Numerous technological innovation and renewal such as fashion design, element lamp multi-dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on.

Technical SpecificationModelAMT3801AAAMT3802AAAMT3803AAOptical SystemInstrument TypeSingle Beam Reflection Achromatic Optics SystemMono ChromometerAchromatic C-T, Focus 350mmDispersion elementsGrating system 1200line/mm characterization area 40x 40mm2
Scintillation wavelength 250nmBandwidth0.1, 0.2, 0.7, 1.4mm AdjustableWavelength Range190-900Wavelength Accuracy± 0.2Wavelength Repeatability≤ 0.1nmResolution Mn 3lines(279.5 & 279.8 Peak and Valley ≤ 30%Spectrophotometric
PropertiesMeasurement A, T, CPhotometric Range0-125%, -0.1-3.00AStatic baseline Drift(Cu) ± 0.003A/30minDynamic baseline Drift(Cu) ± 0.006A/30minBackground CorrectionD-Lamp Background Correction > 50times Correction Ability (1Abs)Atomization SystemFlameGraphite FurnaceFlame/Graphite FurnaceFlameCharacteristic Concentration(Cu)≤ 0.025ug/ml----(Cu)≤ 0.025ug/mlDetection limit (Cu)≤ 0.004ug/ml----(Cu)≤ 0.004ug/mlPrecisionRSD≤ 0.6%----RSD≤ 0.6%Burnertitanium----titaniumNebulizerhigh-efficient Nebulizer----high-efficient NebulizerSpray chamberanticorrosion material----anticorrosion materialSafety measuresFlame fuel gas, power assisted gas abnormal pressure protection----Flame fuel gas, power assisted gas abnormal pressure protectionGraphite FurnaceCharacteristic quantity----Characteristic value
Cd≤ 0.5pg
Characteristic value
Cu≤ 20pgCharacteristic value
Cd≤ 0.5pg
Characteristic value
Cu≤ 20pgDetection Limit----Detection limit Cd≤ 0.8 pgDetection limit Cd≤ 0.8 pgPrecision----Precision Cd, Cu≤ 4%Precision Cd, Cu≤ 4%Temperature Range---- Room-temperature-3000c Room-temperature-3000cHigh-Power Heating Range----1500c-3000c1500c-3000cRamp time & Holding time----1s-255s1s-255sHeating Rate----Max Heating Rate 2000C/SMax Heating Rate 2000C/SAtomization Heating----Optical Control, Time Control, NormalOptical Control, Time Control, NormalProtect Gas Flow Rate out of Graphite Tube----1 L/min1 L/minProtect Gas Flow Rate in Graphite Tube----0-50ml/min micro-flow, 300-400ml/min Fixed-Flow0-50ml/min micro-flow, 300-400ml/min Fixed-FlowSafety measures----Cooling water flow, Protect Gas Pressure, furnace temperature, Graphite Tube AlarmCooling water flow, Protect Gas Pressure, furnace temperature, Graphite Tube AlarmData ProcessTest MannerFlame, Graphite Furnace, hydride-AA, flame emissionConcentrationstandard curve, standard addition, interpolationTimes of repetitiveMeasurement 1-30times, Average Value of A& CReport Printparameters, data resultOtherPCexteriorizationDimension (mm)790x 600x 540790x 600x 540790x 600x 540 x 2Weight (kg)707070+70Power Supply(220± 22)V, (50± 1)HzTemperature range10c ~ 30cHumidity range40% ~ 85%