Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Transformer Test Equipment, Circuit Breaker Test Set, AC Hipot Test Set, DC Hipot Test ..
Establishment:
2005
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Primary Current Injecting Test Set, Current Generator, Large Current Generator manufacturer / supplier in China, offering Primary Current Injection Test System 10000AMPS, Automatic AC Motor Test Bench, Distribution Transformer No Load Loss Test Automatic Transformer Test Bench and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Test Instrument Test Machine China Automatic Impulse Voltage Test System Generator Power Testing System for Lighting Test

China Automatic Impulse Voltage Test System Generator Power Testing System for Lighting Test

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $100000.00/ Piece
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T, PayPal, WesternUnion
Max Diameter of Workpiece: 900mm
Mass Scope of Workpiece: <900kg
Type: Strength Testing Machine

Automatic Impulse Voltage Test System Generator Power Testing System for Lighting Test

General Information:
This impulse test system is used for carrying out standard lightning impulse voltage full wave and operation wave tests on HV apparatus such as power capacitors, clearance, bushings, power transformers and CT/PT at 10kV or below.
Main Parameters for System
Nominal voltage: ±200kV

Impulse capacitance: 0.5µF
Number of stages: 2
Rated stage voltage: ±100kV
Rated energy: 10kJ
Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)
Impulse voltage waveform: generated when load capacitance is 300-3000pF.T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of GB311.1and GB16927.1 standard and IEC standard.
Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.
Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.
Out-of-control rate of synchronous discharge: <5%
Min. output voltage: ≥±20% of rated voltage.
Instability of discharge voltage: <±1.0%
Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.
Above information for reference using, please contact us for further technical details.