1
    YRS
General Supplier

China BS Standard Bare Conductor Dog ACSR

Get Latest Price
Min. Order / Reference FOB Price
1000 Meters US $0.20/ Meters
Local Area: Xinxiang, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Brand: Jinshui
Application: Overhead
Voltage: High Voltage Cable
Current: AC Cable

1. Applications
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

2. Construction
Bare aluminum alloy 1350-H-19 wires, concentrically stranded about a Class A galvanized coated steel core wire.
3. Specifications
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-502 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

4. Manufactured standard
ASTM B-232, BS EN-50182, CSA C 61089, AS/NZS 3607, DIN 48204, IEC 61089, GB/T 1179, JIS 3110

5. Conductor type
Max. cross-section 3500MCM/1750mm2, Max. stranded number 127Nos.

6. Technical Data


Code name
Nominal
Area
Stranding&Wire Diameter
Approx Overall
Diameter
Sectional Area
Approx
Weight
Breaking Load
DC Resistance
Al
Steel
Al
Steel
Total
mm2
mm
mm
mm
mm2
mm2
mm2
Kg/km
KN
Ohm/km
MOLE
10
6/1.50
1/1.50
4.50
10.62
1.77
12.39
43
4.14
2.076
GOPHER
25
6/2.36
1/2.36
7.08
26.24
4.38
30.62
106
9.61
1.0930
WEASEL
30
6/2.59
1/2.59
7.77
31.61
5.27
36.88
128
11.45
0.9077
FOX
35
6/2.79
1/2.79
8.37
36.66
6.11
42.77
149
13.2
0.7822
FERRET
40
6/3.00
1/3.00
9.00
42.41
7.07
49.48
172
15.20
0.6766
RABBIT
50
6/3.35
1/3.35
10.05
52.88
8.82
61.70
214
18.35
0.5426
RACOON
75
6/4.10
1/4.10
12.3
79.2
13.2
92.4
320
27.2
0.3622
OTTER
80
6/4.22
1/4.22
12.66
83.88
13.98
97.86
339
28.80
0.3419
CAT
90
6/4.50
1/4.50
13.50
95.40
15.90
111.30
386
32.70
0.2733
MINK
60
6/3.66
1/3.66
11.00
63.1
10.50
73.6
254.9
21.67
0.4540
HARE
100
6/4.72
1/4.72
14.16
105.00
17.50
122.50
425
36.00
0.3007
HORSE
70
12/2.79
7/2.79
13.95
73.37
42.83
116.20
538
61.20
0.3936
DOG
100
6/4.72
7/1.57
14.15
105.00
13.50
118.50
394
32.70
0.2733
TIGER
125
30/2.36
7/2.36
16.52
131.1
30.6
161.7
602
58
0.2202
WOLF
150
30/2.59
7/2.59
18.13
158.10
36.80
194.90
726
69.20
0.1828