Specifications
1.Single or Twins Ultrasound transducer
2.Built-in thermal printer
3.Certificate:CE
FeaturesSingle or Twins Ultrasound transducerData Graph and Trend Table Review of both mother and fetalBuilt-in thermal printer Programmable alarmsBuilt-in Network capability for connect with central monitoring softwareAll the colors and looks or the parameters can be customizedMulti-face views, select focus on mother or fetal Storage of patient information and dataPerformance SpecificationsDisplay: 8.4" Color TFTResolution: 640x480Display Mode: Standard View, Fetal View, Mother View Indicator: Power indicator light, Alarm soundInterface: Socket for connecting fetal FHR, TOCO, and Fetal Movement
Sensor Socket for connecting mother ECG, NIBP and SPO2 sensor.
Net Socket(RJ45) for communication cable with Central Monitoring Station Software.Power Supply: AC 100 ~ 240V, 50/60Hz, Power < 60VATrend Graph: Resolution from 1s, 5s, 10s. Maximum time 96 hours.Trend Table: Resolution from 1s, 5s, 10s. Review up to 1000 items.Alarm: Adjustable High and Low limits. Three level audible and visual alarm. User Configuration: All the color of parameters and waves can be set according to user willing.Technical specificationsMeet the requirement of IEC60601 seriesDegree of Protection: BFType of Protection: Class II with internal electric power supplyDimention: 92(W)x82(H)x22(D)mm Weight: 136g(with battery)Operation EnvironmentTemperature: 0°C~ +40°C Humidity: 15% ~ 95%Storage EnvironmentTemperature: -20°C~ +60°C Humidity: 10% ~ 95% Patient Range: Pregnant AdultFHRUltrasound Frequency: 2MHz Range: 50 ~ 210 bpm Resolution: 1bmp Accuracy: ±2bmpFETAL MOVEMENTManual fetal movement markSPO2Measurement Range: 0 ~ 100%Resolution: 1%Accuracy: ±2%(70%~100%, Adult/Pediatric, non-motion)
±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecifiedAlarm Range: 0% ~ 100% Refreshing Rate: 1sPulse RateMeasurement Range: 25 ~ 250 bpm Resolution: 1bpmAccuracy: ±3 bpm (non-motion) Alarm Range: 25 ~ 250 bmp Refreshing Rate: 1sECGLead mode: 3-lead or 5-lead Lead selection: I, II, III, AVR, AVL, AVF, VHR range: 15 ~ 300 bpmECG Waveform: 2 channalsAccuracy: ±2bpm or ±2%, which is greaterS-T segment detection range: -2.0mv ~ +2.0mvArrhythmia analysis: 13 kinds of arrhythmia Alarm Range: 15 ~ 300 bpmNIBPMethod: OscillometryMode: Manual/Auto/ContiuousMeasurement Range: 25 ~ 260mmHg Auto Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutesResolution: 1mmHg Overpressure Protection: 300mmHgAlarm range: 25 ~260mmHg