Features:
1. Completely controlled by PC, can flflexibly select the flflame and graphite furnace atomizer (optional).
2. Integrated flfloated optical platform design can obviously improve the optical system shock resistance and keep stable though
use the optical signal for a long term.
3. Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condi
tion of the hollow cathode lamp.
4. Position adjusting: the best height of the flflame burner and can automatically set the front and rear positions.
5. Fully automated wavelength scanning and peak searching.
6. Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong
burner, leakage of the gas, under voltage of air and the abnormal flflameout.
7. Deuterium lamp and self-absorption background regulation
8. Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store
the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
9. Measuring method: flflame absorption method and emission method.
10. Result printing: parameter printing, data result printing and diagram printing
Advanced graphite furnace temperature controlling technology
1.The bringing in of PID technology can effectively overcome
the inflfluence on the temperature rising process caused by the
voltage flfluctuation and the resistance change to make more
accurate controlling process. The combination of the
3ms/time fast sampling technique can make more accurate
and reliable testing data
2.The fast heating capacity can improve the flflexibility of the
elements further
3.Use the ordinary power source of 220V without need of
dynamic power of 380V
4.The maximum procedure heating capacity setting of 20
levels can make a more convenient and easier test of different
samples
5.Three grades adjustable gas flflow can accustom to more
application needs
6.Can timely alarm when the gas and water is stopped and
insufficient gas and water, can avoid the equipment damage
and measuring error
Complete automatic controlling system
Selection of the element lamp
Up-down-front-rear adjustment of the lifter
Adjustment of the optical energy
Selection of the slit
Determination of wavelength scanning and peak searching
Selection of the atomizer
Setting of the background deduction method
Controlling of the gas flflow
Automatic flflaming and flflaming out
Setting of the graphite furnace testing method
Safe, reliable and convenient flflame system
1.EPC can control the flflow of Acetylene (C2H2) more accurate
ly and it is a kind of system which also can operate easily
2.Efficient atomization system enables a higher sensitivity
3.The whole operation system has a high security as the fire
safety system can alarm whenever the electricity is cut off,
abnormal flflame occurs, a lack of pressure happens or the
burner does not match well. And it will automatically turn off
the gas, prohibit tempering. Thus it keeps the operation people
and equipment from harm and damage.
Multi-functional software workstation
1.A workstation that is supported WINDOWS 7
2.The rich menu brings great convenience to the use of
customer
3.Convenient conversion between different menus makes the
operation more easily
4.Various analytical correction methods provide the users
more choices
5.Basic default parameter settings enable even the beginners
can do the normal operation
6.Flexible storage, editing and printing methods give the user
largest support
Specification:
Wavelength range190 - 900nmSpectral bandwidth0.1, 0.2, 0.4, 1.0 and 2.0nmAccuracy of the wavelength±0.15nmReceptivity of the wavelength≤0.04nmbase line stability≤0.002A/30min (Cu)Characteristic viscosity0.02μg/ml/1% (Cu)Checking limit0.004μg/ml (Cu)Preciseness0.50%Grating1800 lines/mmInflamerAll-metal titanium burnerAtomizerEffective glass atomizerLamp stand8D2 background correction abilityWhen the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction methodSize and weight700mmx550mmx450mm 75KgPower source220V±22V AC
S
Acetylene air burner 100mmIgnition dynamic baseline drift ≤0.006A/30min(Cu) Characteristic viscosity≤0.025μg/ml/1%Related standard deviation of the accuracy≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)Safety systemCan automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.
The highest temperature3000ºCThe largest temperature rising speed ≥2000ºC/SCharacteristic quantity Cd≤0.5x10-12g Cu≤0.5x10-11gAccuracy Cu≤3%Cd≤3%Size and weight 550mmx450mmx300mm 65KgSafety system Over current protection
Low air pressure alarm / protection
Low cooling water flow alarm/protectionPower source and power 220V±22VAC7000W