Medical Refirgerator for Lab, Medical Equipment, Deep Freezer manufacturer / supplier in China, offering 278L 328L 450L 936L -25c Upright Biomedical Freezer, Bnfd-P100s Gzl Water Cooled Production Freeze Dryer, Bnfd-H Series Home Freeze Dryer with LCD Touch Screen and so on.
Min. Order / Reference FOB Price | |
---|---|
1 unit | US $4800.00/ unit |
Local Area: | Jian, Jiangxi, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Appliance: | The Analysis of Environmental Samples |
---|---|
Ray Type: | X-Ray Spectrometer |
Gaspath System: | Double |
7-inch color touch screen, display the flflow rate
and pressure value of the electronic gas path.-
Computer anti-control (need to choose PC-side
anti-control software) and the host touch screen
to achieve synchronous two-way control
7-inch color touch screen, display the flflow rate and pressure value of the electronic gas path.
Computer anti-control (need to choose PC-side anti-control software) and the host touch screen to
achieve synchronous two-way control.
Multi-core, 32-bit embedded hardware system to ensure reliable operation of the instrument.
One key to start function.
The extensible synchronous external triggering function can be initiated by external signals (autosam
pler, thermal analyzer, etc.) at the same time to start the host and workstation.
Perfect system of self-test function and automatic fault identifification.
Extended interface with 8 external events, which can be equipped with various function control valves
and operate according to their own timing.
20 sets of sample test mode can be stored by memory
RS232 communication port
Product specification:
WWW.BOYININSTRUMENT
Column ovenInner volume22LTemperature rangeRT+ 5°C - 400°CTemperature control accuracy± 0.1 °CTemperature programming9 stepProgram Total Time9999.9 minMax. Heating rate0.1 - 60°C / minMax. cooling rate≤ 10 mins (250°C -50°C)
Sample injectorTemperature rangeRT+ 7°C - 420°CTemperature control typeIndependentCarrier gas flow control typeconstant pressureMax quantity of simultaneous installations3PCSInjection unit typepacked column or splitSplit ratioSplit ratio displayPre column pressure range0 - 400kpaPre column pressure accuracy0.1kpaFlow setting rangeH2 0-200ml / min
N2 0-150ml / min
DetectorOptionalFID, TCDTemperature control rangeRT+7 ºC - 420 ºCMax quantity of simultaneous installations2Ignition typeautomatic
Hydrogen flame ionization detector (FID)Logarithmic amplifierHigh Voltage Switch Controlbaseline signal displayDetection limit: ≤ 3 x 10-12 g / s (sample: n-hexadecane)baseline noise: ≤ 5 x 10-14 A≤ 5 x 10-14 Abaseline drift: ≤ 6 x 10-13 A≤ 6 x 10-13 ADynamic range10RSD≤ 3%
Thermal Conductivity Detector (TCD)Sensitivity5000mV.ml / mg (sample: n-hexadecane)baseline noise≤ 0.05 mVbaseline drift≤ 0.15 mV / 30 minDynamic range10
Overall dimension & weightPower220V ± 22V, 50Hz ± 1Hz, 3000WPacking dimension740 x 730 x 800mmG.W.70kg