Surgical Face Mask, Disposable Face Mask, Disposable 3-Ply Face Mask manufacturer / supplier in China, offering Medical Non-Woven Surgical Face Mask Disposable with Tie-on Bfe>99%, Medical Protection Face Shield, Cheapest Gun Shape Baby Non-Contact Infrared Forehead Thermometer and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Pieces | US $9000.00/ Pieces |
Local Area: | Chengdu, Sichuan, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Classification: | Imaging Diagnostic Equipment |
---|---|
Type: | Ultrasound Scanner |
Certification: | CE, FDA, MSDS, ISO13485 |
Imaging Modes:
l B, B|B, 4B, B|M, M
l Color Doppler (CFM)
l Power Doppler (PDI)
l Directional Power Doppler (DPDI)
l Pulsed Wave Doppler (PWD)
l Continuous Wave (CW)
l B+PWD (Duplex)
l B+CFM/PDI/DPDI+PWD (Triplex)
l High Pulse Repetition Frequency (HPRF)
l Tissue Harmonic Imaging (THI)
l Compound
l Trapezoid
Scanning Method:
electronic linear, electronic convex, electronic microconvex, electronic phased array;scanning depth: 2-750px
Color Doppler:
l PRF variable: 0.5-9 kHz0.5-15KHz
l wall filter settings: 3 steps (5%, %10%, 15% PRF)
l angle steering for linear transducers: ±10°±30°
l real-time spatial filter: 4 values
l CFM palette>10 maps
l PDI palette>10 maps
l B/Color priority control
l color threshold control
l CFM baseline control
l Doppler frequency selection
l color frame averaging
l Transparent Color Mapping (TCM)
Pulsed Wave Doppler:
l PRF variable: 1-10 kHz0.5-15KHz
l wall filter settings: 16 steps (2.5%-20% PRF)
l angle steering for linear transducers: ±10°±30°
l real-time trace line with automatic calculation of spectrum parameters
l stereo sound: volume control
l PWD palette>10 maps
l Doppler frequency selection
Our Keyboard
Main technical
YSD680 Main Technical Parameters Scanning mode:B, B/B, 4B, B/M, M, B+C, B+D, B+C+D, PDI, CF, CW etcProbes: Convex array probe: R50 (Frequency=2.0/3.0/3.5/4.0/5.5 MHz);High Frequency Linear Array Probe: L40 (Frequency = 6.0/ 6.5/ 7.5/ 10/ 12 MHz);Trans Vaginal Probe: R10 (Frequency=5.0/6.0/6.5/7.5/9.0 MHz); L20 (Frequency=2.0/2.1/3.5/4.0/5.0 MHz).Transducer Ports:4Depth:≥300mmLateral Resolution:≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm)Axial Resolution: ≤1mm (Depth≤80mm) ≤2mm (80< Depth≤130mm)Blind Area:≤5 mmGeometry Position Precision:horizontal≤10% vertical≤10%Channels: 64Displayer:15 inch LCD (PAL displayer is optional)External Display:PAL, VGAUSB Ports: 2Gray scale: 256 levelsVoltage:AC220V ±10%Current:3AUPS-DP:DC12.8V, 11.5AInput power:≤ 300VA