CE and FDA Approved Wrist Pulse Oximeter
Instructions
The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.
Major Features
Small in volume,light in weight and convenient in carryingOperation of the product is simple, low power consumptionSpO2 value displayPulse rate value display, bar graph displayPulse waveform displayScreen brightness can be changedA pulse rate sound indicationWith measured data overruns limits and low-voltage alarm function, the upper/down alarm range can be adjustableWith clock functionBattery capacity indicationLow-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage, and with alarm functionWith SpO2 value and pulse rate value of storage, the storage data can be uploaded to computersReal-time data can be transmitted to computers(only for the Lei Mo probe)Connected with an external oximeter probeMain performance
Display Mode: 1.3" 65K Color OLED displayScreen Resolution: 128*96SpO2 Measuring Range: 0%~100%(the resolution is 1%)Accuracy: 70%~100%: ±2%, Below 70% unspecified.PR Measuring Range: 30bpm~250bpm(the resolution is 1bpm)Accuracy: ±2bpm or ±2% (select larger)Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.Power Consumption: less than 100mAVoltage: DC 3.6V~4.2VPower Supply: Voltage 3.7 rechargeable lithium battery x 1 Battery working hour: The theoretical number is 20 hoursBattery working life: Charge and discharge no less than 500 times.Safety Type:Interior Battery, BF TypePhysical Identity
Dimension: 61(L) x 56(W) x 24 (H) mm
Weight: about 60g (with the lithium battery*1)
Certification
CE, FDA