Business Type:
Manufacturer/Factory
Business Range:
Biochemistry Hematology Analyzer, Anesthesia, Ultrasound, X-Ray System, Patient Monitor, ..
Establishment:
2012
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
Domestic, Others
OEM/ODM Service
Sample Available

Biosafety Cabinet, Biosafety Box, Laboratory Euqipment manufacturer / supplier in China, offering Laboratory Bisosafety Cabinet /Biological Furniture with Class 2 Certification, Hospital Equipment Digital B/W Ultrasound for Abdomen, Hospital Equipment Portable Ultrasound Scanner with Ce and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Clinic Toxicology Automatic Chemistry Analyzer Yj-300

China Clinic Toxicology Automatic Chemistry Analyzer Yj-300

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $3500.00/ Piece
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Classification: Biological Diagnostics
Type: Biochemistry Analyzer
Certification: CE

Advanced Hospital Bench Top Automatic Chemistry Analyzer (YJ-300)
Product Description
High End Full Automatic biochemistry analyzer
Specification:
Throughput constant 300T/h,
Closed integrated photovoltaic systems, no mechanical parts,maintenance free
Minimum reaction volume is 150ul,cost saving
Discrete,random access,automatic
Random choice of method, the real discrete automatic chemistry analyzer
This automatic chemistry analyzers have gained a lot of national patents during the researching.

Analyze Unit
l Throughput: constant 300 T/h, 81 reaction cuvette positions,multi-channel testing together.
l Minimum reaction volume is 150μl, cost saving.
l Determined by the sample sequence, inserted at any time emergency.
l Heating method: Direct thermal solid thermostat closed.
Optical Unit
l Closed integrated photovoltaic systems, no mechanical parts,maintenance free.
l Light Source:Halogen-tungsten lamp;
l Lifetime≥2000 h.
l 8 Wavelength,support single or dual wavelength.
Reagent Unit
l 80 reagent positions.
l Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
l 15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
l Support for single and double reagent, reagent completely open.
Internal barcode reader (option).
Sample Unit
l 80 sample positions.
l Testing according setting,random access.
l Real time display of testing status.
l Internal barcode reader (option).
Reagent/Sample handing Unit
l Intelligent liquid detection & collision protection (Red light: collision; Blue light: detection of the liquid).
l Reagent volume: 2 ~ 100μl,step by 1μl .
l Probe cleaning:automatically washing for both inside and outside,carry over0.1%.
l Automatically dilute and retest.
Calibration and quality control Unit
l Linear curve type:Single-point linear,two-point linear and multi-point linear.
l Nonlinear curve type:Logit-4p,Logit-5p,polynomial,factor.
l Automatically use best calibration curve and standard.
l Quality control chart:L-J,Westgard TwinPlot,Cumulative.
Operation Unit
l Operation system: Windows XP/Office 2000,interface is intuitive and operate it easily, arbitrary operating authority;No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
l Can print the contents of any custom;Offers a variety of print formats.
l Help and operation guide on line in English.
l No restrictions on setting test parameters.
l Unique password for user management,rational allocation of user rights.
l Real time display of testing status,the remaining amount of reagent,testing status ,reaction curve and the test progress.
l Real time display of reaction plate temperature.
RS-232 standard interface,support for the hospital network, print reports remotely.

Others
l Temperature:15-30 degree
l Humidity:35-85%.
l Try to avoid strong light.
l Floor level up:less than 1/200.
l Barometric:86.0kPa-106.0kPa.
l Power Supply:AC 220V-240V 50/60Hz±1 Hz. 1000W or 100V-200V 60HZ 1000W
l Water consumption:less than 18L/h.
l Frequency:550 VA.
l Dimension:912mmx721mmx570mm
l Weight:60kg

Test projects
l ALT,AST,TP,ALB,TBIL,DBIL,ALP,r-GT,CHE,TBA,5-NT
l UREA,CR,UA,TCO2
l CHOL,TG,HDL,LDL,ApoA,ApoB,LPa
l AMY,LIP
l GLU,GSP
l CK,CK-MB,a-HBDH,LDH,MB
l CRP,RF,ASO

YJ-300
Automatic Chemistry AnalyzerSpecificationsAnalyze UnitThroughputConstant 3000T/h (non-ISE)TheoryAbsorption spectrometry, transmission turbidimetryMethodologyEnd-point Fixed-timeKineticIon selective electrodeTest according set up, random accessReaction plateContain 120 reaction cuvettesMaximum reaction time15 minutesMinimum reaction volume150 ulMaterial of cuvettesSpecial UV-transparent optical glassCuvettes useAutomatically cuvettes washingOptical UnitLight SourceHalogen-tungsten lampPhotometerReversed opticsWavelength340nm-670nm wavelength optionAbsorption0-4.0 Abs(10mn conversion)Reagent UnitReagent plate80 reagent positions ,support for single and double reagent, reagent completely openReagent storage temperature4~10 degreeReagent bottle15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 mlReagent volumeR1:150-300 ul,R2:20-150ul step by 1.0 ulReagent/Sample ProbeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.Sample UnitSample plate120 sample positionsSample typeHuman (animal) serum plasmaurine etc.Samples cupSupport one-off micro cupsSample volume2-100 ul, step by 0.1 ulSample/reagent probeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.Temperature control UnitHeating methodDirect thermal solid thermostat closedTemperature equilibrium time<3 minutesReaction temperature37 ±0.1 degreeTemperature fluctuation±0.1 degree Operation UnitSoftwareWindowsXP 2000DatabaseSQL ServerData StorageAutomatic store & copy; No time and volume limit; Lifetime preservationPrint formatCan be set up, offer several standard formatCalibration modeLinear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standardQuality control methods :Real time, within day & between dayQuality control diagramL-J cumulativetwin plotStatus displayReal time monitoring of reagent residual volume .Running status of reagent tray, samples trayAdjustmentDynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messagesSettingOperation permission setting, Item setting, cross pollution setting, cuvette blank settingOthersWater consumption : < 18L/hPower Supply :AC 220V-240V 50/60Hz 1000W or 100V-200V 60HZ 1000WFrequency :Maximum 600VADimension :912mmx721mmx570mmNet Weight : 60kgAccessory :Software


Note:We provides you with12-24 months free repair guarantee for main unit, 12 months free repair guarantee for probe and 6 months free repair guarantee for the optional parts respectively.More information for our products and service,please turn to our official website or contact us directly.