Load Cell
Dimension:
Sales points/ Focus:
*Quality always comes first
*Reasonable Prices
*OEM service provided
*Responsible after-sales service
*Aiming to get repeat orders from 80%customer after the trial orders
*Making progress with customers together
QC Team:
QC team with more than 20 professional and technical personnel. To ensure 100% products checking.
Material: Strictly control of material using, meet international requested standards.
Semi-finished products inspection: Product inspection before 100% finished.
Production line test: With work team or data engineer who will inspect machines and lines at fixed period.
Finished Product Inspection: Quality and property test before products are packed and loaded.
Contact
We will reply your email or fax within 24 hours.
You can call us at any time if there is any question on our production.
If you want to know more information, please contact us without hesitate.
MODEL HMD2015CC5COMPREHENSIVE ERROR C3OUTPUT SENSITIVITYmV/V2.0 ± 0.25%NonLINEARITY %F.S. ± 0.02± 0.03REPEATABILITY %F.S.0.020.02HYSTERESIS %F.S.± 0.02± 0.03CREEP (30min) %F.S± 0.02± 0.03TEMP. EFFECT ON ZERO%F.S/10 °C≤ 0.002≤ 0.003TEMP. EFFECTOUTPUT %F.S/10 °C≤ 0.002≤ 0.003ZERO OUTPUT %FS ± 1± 1INPUT RESISTANCE Ω400 ± 30OUTPUT RESISTANCE Ω 350 ± 3INSULATION RESISTANCE M Ω ≥ 5000EXCITATION VOLTAGEV ( DC/AC ) 5 ~ 12OPERATION TEMP. RANGE °C -30 ~ +80 OVERLOAD CAPACITY %F.S.150CAPACITY 10~100t IP67