Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Ultraviolet Sterilizer, Water Descaling Equipment, Water Filter, Sand Filter, Water ..
Establishment:
2004
R&D Capacity:
OwnBrand, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Water Treatment Plant, Water Treatment, Water Softener manufacturer / supplier in China, offering 5000 Liter/Hour Automatic Water Softener with Duty / Standby, Contaminants and Chlorine Removed From Water by Activated Carbon Filter, Skid Installation 4000L/Hr Water Softener System Effectively Reduced Scale Build-up in Pipes and so on.

1
    YRS
General Supplier
Supplier Homepage Industrial Equipment & Components Environment Protection Device Water Disinfection System China Commercial Ultraviolet Water Sterilizer Systems UV Disinfection Equipment

China Commercial Ultraviolet Water Sterilizer Systems UV Disinfection Equipment

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $6500.00/ Set
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Certification: ISO9001, UL, CE
Application: Industry
Voltage: 220V


Specification:
Ultra violet radiation is natural source of purification.
Ultra violet radiation band of invisible light in the electromagnetic spectrum, in the range of 200 - 400 nm wavelengths.
The U.V. wavelength of 253.7 nm possesses the greatest germicidal effectiveness, which Penetrate the microbial cell membrane to destroy the DNA molecule thus preventing cell Replication.
U.V. is used to provide Bacterial Disinfection in water. It does not change the Physical or Chemical Characteristics in water. U.V. provides disinfection On Contact. It does not have any residual properties left in treated water.
Special High Germicidal Lamps produce high U.V. output in 254 nm range.
There are no know micro organisms resistant to U,V,
U.V. water purification is preferred the world over because it is the simplest & most practical means of destroying micro organisms in water.
Advantages of UV sterilizer
No chemicals added to the water supply - no byproducts, (i.e. chlorine + organics = trihalomethanes).
Environmentally and user friendly, no dangerous chemicals to handle or store, no risks of overdosing.
Easy installation, only two water connections and a power connection.
No change in taste, odor, pH or conductivity or the general chemistry of the water.
More effective against viruses than chlorine.
Extremely economical, hundreds of gallons may be treated for each penny of operating cost.
Immediate treatment process, no need for holding tanks, long retention times, etc.
Automatic operation without special attention or measurement, operator friendly.
Simplicity and ease of maintenance, periodic cleaning, (if applicable), and annual lamp replacement, no moving parts to wear out.
No handling of toxic chemicals, no need for specialized storage requirements.
Low initial capital cost as well as reduced operating expenses when compared with similar technologies such as ozone, chlorine, etc.
How Ultraviolet Disinfection System Works
As water flows past the UV lamp(s) in a UV disinfection system, microorganisms are exposed to Ultraviolet light energy. Ultraviolet light alters the DNA material in cells so that bacteria, viruses, molds, algae and other microorganisms can no longer reproduce. The microorganisms are considered dead, and the risk of disease from them is eliminated. These Ultraviolet Disinfection Systems are designed for commercial & industrial applications. The process of UV Disinfection is accomplished without adding any harmful chemicals to your drinking water and does not distort the water or effect its pH value. UV Disinfection has an effective kill rate of 99.99% of most living microorganisms such as bacteria & viruses.
What Contaminants Do UV Sterilizers Remove?

There are no micro-organisms known to be resistant to UV, unlike chlorination. UV is known to be highly effective against bacteria, viruses, algae, molds and yeasts, and disease causing oocysts like cryptosporidium and giardia. In practice, bacteria and viruses are the cause of most major waterborne pathogenic diseases. Of these enteric viruses, hepatitis virus and Legionella pneumophila have been shown to survive for considerable periods in the presence of chlorine, but are readily eliminated by UV treatment. For most microorganisms, the removal efficiency of UV for microbiological contaminants such as bacteria and virus generally exceeds 99.99%.

ConVENTIONAL METHODS OF WATER TREATING CHLORINEOZONEULTRA VIOLETCapital costLowestHighLowEase of installationGoodPoorExcellentEase of MaintenanceGoodPoorExcellentCost of MaintenanceMediumHighLowestOperating CostLowHighLowFrequency Of MaintenanceFrequentContinuousV. InfrequentControl SystemPoorGoodExcellentVirucidal EffectGoodPoorGoodToxic ChemicalYesYesNoResidual Effect Problem withYesYesNoHazardsHighYesLow to noneContact Time30 - 60 minutesHigh1 - 5secondsDisinfection PerformanceLeaves some pathogensKills all microbesKills all microbesEffect on WaterOrganochlorine compounds, Taste & pH changesUnknownNoneThe Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed.


Applications
UV disinfection is an effective, safe, and economical treatment method currently used world-wide in various industries, from municipal water treatment plants to private businesses, and industrial plants. Below are the potential applications of the UV systems:

1. Mineral water production
2. Wastewater: municipal sewage, hospitals, industrial plants, oil-fields;
3. Drinking water: tap water, office buildings, surface water (well, lake, river);
4. Technical water: food and beverage production, electronics, cosmetics, etc.);
5. Water recycling: swimming pools, fountains, landscape design, cooling towers;
6. Aquariums and fisheries;
7. Irrigation in agriculture and hydroponics;
8. Decomposition of TOC, ozone, chlorine residuals, and chloramines;
9. Disinfection of thick liquids:protein solutions, syrops, juice concentrates;
10. Mobile treatment for army, field camps, ships, airplanes, etc.

Technical parameters:


model
capacity
Power
inlet-outlet
reactor
panel
Anchor
G weight

m³/hour
watt
mm
LxWxH
cm
screw
Kg
YLCn-005
0.3
16
1/2″
30x6x11
without
without
5
YLCn-008
1
25
1/2″
47x6.3x11
without
without
10
YLCn-050
2
40
1″
100x9x20
Φ8.9x25
(dxL)
69x4xΦ1
25
YLCn-150
6
80
1+1/4″
100x11x23

69x4xΦ1
30
YLCn-200
8
120
1+1/2″
100x15.9x30
Φ8.9x45
(dxL)
69x7xΦ1
35
YLCn-300
12
160
2″
100x15.9x32

69x7xΦ1
40
YLC-050
2
40
DN25/1″
100x8.9x30
25x30x12
(WxHxD)
60x4xΦ1
45
YLC-150
6
80
DN32/11/4″
100x10.8x30

60x4xΦ1
50
YLC-200
8
120
DN40/11/2″
100x15.9x40

60x7xΦ1
60
YLC-300
12
160
DN50/2″
100x15.9x40

60x7xΦ1
70
YLC-360
15
200
DN65/21/2″
100x15.9x40

60x7xΦ1
120
YLC-500
20
240
DN65/21/2″
100x21.9x50

60x11xΦ1.2
130
YLC-600
25
280
DN80/3″
100x21.9x50

60x11xΦ1.2
140
YLC-700
30
320
DN100/4″
100x21.9x50

60x11xΦ1.2
150
YLC-1000
40
360
DN100/4″
100x21.9x50

60x11xΦ1.2
160
YLC-1200
50
400
DN125/5″
100x21.9x50

60x11xΦ1.2
180
YLC-1500
60
420
DN150/6″
170x27.3x57

120x16xΦ1.4
210
YLC-2000
80
560
DN150/6″
170x27.3x57

120x16xΦ1.4
220
YLC-2500
100
700
DN150/6″
170x27.3x57
60x128x30
(WxHxD)
120x16xΦ1.4
275
YLC-3000
125
840
DN150/6″
170x27.3x57

120x16xΦ1.4
300
YLC-4000
150
1120
DN200/8″
173x32.5x65

120x20xΦ1.6
325
YLC-5000
200
1400
DN200/8″
173x37.7x72

120x22xΦ1.6
350
YLC-7000
300
2100
DN250/10″
175x42.6x80

120x24xΦ2.0
400
YLC-10K
400
2520
DN250/10″
176x52.9x95
60x150x40
(WxHxD)
120x22xΦ2.2
475
YLC-15K
600
3080
DN300/12″
176x78x110

120x32xΦ2.4
600
YLC-20K
800
3920
DN350/14″
Designated
Designated
Designated
Designated
YLC-25K
1000
4760
DN350/14″
Designated
Designated
Designated
Designated



Typical Maintenance Requirements
UV lamps (bulbs) require annual replacement to ensure optimal performance. UV lamp performance, just like any other light source, will slowly diminish over time. Beyond one year, there is no assurance that the UV light emitted from the bulb will provide sufficient disinfection. Remember, UV light cannot be seen. The bulb may still produce light, but not necessarily UV rays. The quartz sleeve does not need replacement unless it gets broken, however, it should be cleaned several times per year (outside only).
Frequently Asked Questions about Ultraviolet (UV) Purification
Q. How do ultraviolet ("UV") sterilizers work?
A. UV sterilizers work by exposing water to powerful germicidal ultraviolet light. DNA and protein links in bacteria are destroyed by exposure to this light.
Q. Does the water become radioactive by this radiation?
A. No. No radiation residual or any chemical residual is left in the water as a result of the UV rays.
Q. Do these systems come in different sizes?
A. Yes. The size of the systems is directly proportional to the flow rate of the water in gallons per minute. The higher the flow rate, the larger the system and lamp.
Q. Does the water have to sit in the UV sterilizer to be disinfected?
A. No. If the system is sized correctly, the water is disinfected as it flows through.
Q. What if the water flows faster than is allowed through the system?
A. If the flow rate exceeds the design flow rate of the UV sterilizer, then there is a possibility that the water will not be properly disinfected. It is important to use a flow restrictor so that the flow rate cannot be exceeded.
Q. How long does the lamp last?
A. The lamps last approximately 10,000 hours. That is why we recommend replacement approximately every 12 - 14 months of continuous operation. After this period, the lamp itself becomes solarized and blocks the rays form entering the water.
Q. Are these systems bigger energy users?
A. No. The 12 gallon per minute model, for instance uses only 39 watts, about half the amount an ordinary light bulb uses.