Business Type:
Manufacturer/Factory
Business Range:
MCCB, Contactor, Circuit Breaker
Establishment:
2007
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion, Small-amountpayment
Main Markets:
Europe, Southeast Asia, Middle East, Australia
OEM/ODM Service
Sample Available

Automatic Transfer Switch, ATS, Change Over Switch manufacturer / supplier in China, offering PC Class ATS Change-Over Switch 16-3200A Automatic Transfer Switch for Generator, Sq5 Manual Changeover Switch ATS Electrical Changeover Switch, 20ka-40ka DC500V Solar DC Surge Protector and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Switch Other Switches China Cps Kbo Control Protection Switch Switching

China Cps Kbo Control Protection Switch Switching

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $70.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion, Small-amountpayment
Operation: Electric Type
Installation: Fixed
Speed: Normal Type Circuit Breaker

Cps Kbo Control and Protection Switch Switching125A 45A

KBO,CPS (Basic Type KB0 4-Pole):

1) CPS is intended to be connected to circuits of rated voltage not exceeding 690V, and rated current from 0.16A to 125A, 50Hz(60Hz) a. C, available for making, carrying and breaking currents under normal conditions including specified operating overload conditions, and also available for making, carrying for a specified time and breaking currents under specified abnormal conditions (such as short-circuit current)

2) Main technical data

- Two outline dimensions(C and D frame size)
- 3-pole and 4-pole
- Current ratings: 12, 16, 18, 32, 45, 63 and 100A
- Min. Setting current: 0.16A; Max. Setting current: 100A
- Short-circuit break capacity: 35kA for type C(Economic); 50kA for type Y (Standard); 80kA for type H(High capacity).
- Opening time under prospective short-circuit current is 2-3ms, at current limiting of 0.2 and below.

Inm frame current

Rated current of main body In(A)

Rated current of intelligent controller le(A)

Current setting of short delay triiping Ir2(A)

Current setting of long delay triiping Ir1(A)

Controllable capacity at 380V(KW)

Usage category

45

12
16
18
32
45

0.4

0.48-4.8

0.16-0.4

0.05-0.12

AC-42
AC-43
AC-44

1

1.2-12

0.4-1

0.12-0.33

2.5

3-30

1-2.5

0.33-1

4

4.8-48

1.6-4

0.33-1.6

6.3

7.5-75

2.5-6.3

1-2.5

12

14.4-144

4.8-12

2.2-5.5

16

19.2-192

6.4-16

2.5-7.5

18

21.6-216

7.2-18

3.0-7.5

25

30-300

10-25

5.5-11

32

38.4-384

12.8-32

5.5-15

40

48-480

16-40

7.5-18.5

45

54-540

18-45

7.5-22

6.3

7.5-75

2.5-6.3

1-2.5

125

16
18
32
45
50
63
100
125

12

14.4-144

4.8-12

2.2-5.5

16

19.2-192

6.4-16

2.5-7.5

18

21.6-216

7.2-18

3.0-7.5

25

30-300

10-25

5.5-11

32

38.4-384

12.8-32

5.5-15

40

48-480

16-40

7.5-8.5

45

54-540

18-45

7.5-22

50

60-600

20-50

7.5-22

63

75.6-756

25.2-63

11-30

80

96-960

32-80

15-37

100

120-1200

40-100

18.5-45

125

150-1500

50-125

22-55

a.With control and protection from common characteristic

SCPS series control and protective switching devices with control and protection functions,

equivalent circuit breaker ( fuse ) + auxiliary electrical overload relay contactor.

Very good solution to the separation element cannot or difficult to solve element between the

protection and control characteristics matching problem, so that the protection and control

characteristics with more perfect and reasonable with inverse time limit, and the instantaneous

protection characteristic of three segments .

b.With the operation reliability and continuous system operation performance

SCPS in breaking short circuit current without maintenance can be put into use, that is breaking

short circuit faults of continuous running performance: SCPS in the breaking short-circuit current after the test, is not less than 1500 AC-44 electric service life,

which is composed of circuit breakers and other separation components the system is difficult to

achieve, SCPS of this feature of the system is greatly improved the reliability of operation and

system integration of continuous operation, the Ics 80kA index is similar products in the leading

international, domestic highest index.

c. Saving energy and material:

SCPS has the advantages of small volume, small installation area, without a separate component

contacts, reduce line heating, energy saving, material saving etc..

d. With high breaking capacity, arcing distance short of the characteristics

SCPS in 380V rated short-circuit breaking capacity ( Ics Oco-co ) reached high

breaking type 80kA, type 50kA, type of economic standard for 35kA, 50kA expected in

short circuit current breaking time is 2 ~ 3MS, limiting factor reached 0.2 the following,

reaching the leading level of molded case circuit breakers.

e. Installation of flexible

Horizontal, vertical, horizontal installation the installation does not affect the use of performance.

Can be widely used in compact sets of devices, including a fixed type or a drawer type MCC

cabinets, especially SCPS 12, 16, 18, 32, 45 in 1 / 4 and 1 / 2 Drawer in the application, with

separate components incomparable superiority.

#MmZyqWKmgjSTips { Z-INDEX: 999999999; POSITION: absolute; WIDTH: 56px; HEIGHT: 24px; LEFT: 1342177.27em } #MmZyqWKmgjSTips A { LINE-HEIGHT: 24px; MARGIN: -32px 0px 0px; PADDING-LEFT: 23px; WIDTH: auto; DISPLAY: block; BACKGROUND: url(http://mat1.gtimg.com/www/sogou/sogou_tips_v1.png) no-repeat 0px 0px; HEIGHT: 24px; COLOR: #000; FONT-SIZE: 12px; TEXT-DECORATION: none; _position: relative } #MmZyqWKmgjSTips A:hover { BACKGROUND-POSITION: 0px -34px; COLOR: #45a1ea }

#MmZyqWKmgjSTips { Z-INDEX: 999999999; POSITION: absolute; WIDTH: 56px; HEIGHT: 24px; LEFT: 1342177.27em } #MmZyqWKmgjSTips A { LINE-HEIGHT: 24px; MARGIN: -32px 0px 0px; PADDING-LEFT: 23px; WIDTH: auto; DISPLAY: block; BACKGROUND: url(http://mat1.gtimg.com/www/sogou/sogou_tips_v1.png) no-repeat 0px 0px; HEIGHT: 24px; COLOR: #000; FONT-SIZE: 12px; TEXT-DECORATION: none; _position: relative } #MmZyqWKmgjSTips A:hover { BACKGROUND-POSITION: 0px -34px; COLOR: #45a1ea }

#MmZyqWKmgjSTips { Z-INDEX: 999999999; POSITION: absolute; WIDTH: 56px; HEIGHT: 24px; LEFT: 1342177.27em } #MmZyqWKmgjSTips A { LINE-HEIGHT: 24px; MARGIN: -32px 0px 0px; PADDING-LEFT: 23px; WIDTH: auto; DISPLAY: block; BACKGROUND: url(http://mat1.gtimg.com/www/sogou/sogou_tips_v1.png) no-repeat 0px 0px; HEIGHT: 24px; COLOR: #000; FONT-SIZE: 12px; TEXT-DECORATION: none; _position: relative } #MmZyqWKmgjSTips A:hover { BACKGROUND-POSITION: 0px -34px; COLOR: #45a1ea }