Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Anaesthesia Machine, Ventilator and Accessories, etc
Establishment:
2001
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Anesthesia Machine, Good Anaesthesia Machine, Medical Machine manufacturer / supplier in China, offering Medical Equipment Anaesthesia Machine Cwm-301A, Medical Equipment Featured-ICU Ventilator Cwh-3010A, Beta 15 Monitor and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Physical Therapy Equipment China Cwz-830 Double Channel Syringe Pump Cwz-830

China Cwz-830 Double Channel Syringe Pump Cwz-830

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $99999.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Type: Medical Equipment
Theory: Syringe Pump
LCD Display: Without LCD Display
Features & Functions:
Three working modes: Rate mode, time-volume mode, dosage-weight mode.
Unique Human Voice Alarm system and accurate injection rate make the injection process safer and mor e reliable.
Have store many brands syringes, Automatically calibration and compatible with any brand syringes.
Large LCD screen displays working status.
KVO and Bolus functions.
Two channels can work independently or together.
Technical parameters:
Product nameCWZ-830 Double Channel syringe pump
Flow rate50ml syringe: 0.1~1500ml/h; 30ml syringe: 0.1~900.0ml/h; 20ml syringe: 0.1~600.0ml/h; 10ml syringe: 0.1~300.0ml/h
The range of limiting volume0~999.9mlThe range of injected volume0~9999.9ml
Accuracy of flow rateWithin ± 3%(Choose the syringe of specified manufacturer correctly. This accuracy of flow rate is not including the errors of syringe itself. )
Purge ratePurge rate of 50ml syringe: 1500ml/h; Purge rate of 30ml syringe: 900.0ml/h; Purge rate of 20ml syringe: 600.0ml/h; Purge rate of 10ml syringe: 300.0ml/h
Alarm and warmsThe pump can give out alarming when injection soon finish, injection finishing, injection of limited amount finished, injection is blocked, syringe falls off, syringe is improperly installed, setting error, AC power has been pulled out, low battery and so on.
Injection blockedChoose in the three kinds of occlusion alarm pressure according to the clinical requirements(High, Medium, Low)
KVO rate1ml/hFuse specificationF1AL/250V, two fuses(installed inside pump)
Operating powerAC100~240.0V, 50/60Hz, Power: ≤ 30VA
Internal rechargeable battery: DC 11.1V, capacity≥ 1600mAh. The device could work constantly more than 4 hour at medium speed running mode, after the battery charged for 10 hours.
Atmospheric pressure860hPa~1060hPa
Safety levelClass II with insulated enclosure, internal power supply, BF-type continuous normal running equipment.
IP gradeIPX1
Dimensions280(L)x 210(W)x 255(H)(mm)Weight3.6kg
AccessoriesPower line, operating manual, warranty card, product certification.