Brine to Water Heat Pump, Water to Water Heat Pump, Geothermal Heat Pump manufacturer / supplier in China, offering Brine to Water Heat Pump with Copeland Compressor and R410A Refrigerant, Water to Water Heat Pump, Geothermal Heat Pump, Swimming Pool Heat Pump Water Heater with High Component (SP05P-E5), Large Air Source Heat Pump with Long Warrenty Hw60p ( and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Heating, Refrigeration & Temperature Control Heat Pump China DC Inverter Air to Water Heat Pump Monoblock Type for Cooling + Heating

China DC Inverter Air to Water Heat Pump Monoblock Type for Cooling + Heating

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $2300.00/ Piece
Local Area: Jiaxing, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Certification: SASO, CCC, ISO9001, CE, TUV
Working Medium: R410A
Heat Source Type: Air Source Heat Pump
KonNEN DC INVERTER AIR SOURCE HEAT PUMP, FOR COOLING +HEATING:

* GMCC Compressor with R410A;* High efficiency hydrophilic aluminum foil fin heat exchanger;* "SANHUA" EEV;* "Lifeng" fan ;* Delivery time:about 30days after received deposit;* Payment:T/T 30% prepaid ,then pay for the balance before delivery;*Package:ply-wood cases;* Warrenty:18month;


WE SUPPLY OEM SERVICE!
KonNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KonNEN NEW PROJECTS:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
KonNEN HEAT PUMPS LOADING:
PARAMETERS TABLE:

ModelRF8I/bdRF12/bdRF16I/bdPower Supply V/Ph/Hz220/1/50Rated Current Input Without E-heater (A)202430Rated Condition 7ºCHeating Capacity (KW)8.81217Power Input (KW)2.553.554.91COP3.453.43.5Nominal Condition -12ºCHeating Capacity (KW)5.41 10.50 12.13 Power Input (KW)2.25 4.40 5.05 COP2.40 2.40 2.40 Low Temp. Condition -20ºCHeating Capacity (KW)4.78 9.21 10.52 Power Input (KW)2.45 4.56 5.18 COP1.95 2.02 2.03 Low Temp. Condition -25ºC/Water output temp. 41ºCHeating Capacity (KW)3.55 6.82 7.80 Power Input (KW)2.20 4.21 4.81 COP1.61 1.62 1.62 Low Temp. Condition -25ºC/Water output temp. 50ºCHeating Capacity (KW)3.19 6.14 7.02 Power Input (KW)2.28 4.23 4.91 COP1.40 1.42 1.43 Rated Cooling ConditionCooling capacity (KW)8.00 11.50 12.00 Power input (KW)3.20 4.60 4.80 EER2.50 2.50 2.50 Max. Water Output Temp. Under Ambient Temp. -25ºC56.2ºC56.1ºC56.2ºCNoise Level dB(A)59.560.561.5RefrigerantR410AR410AR410AWater Flow1.38 m³/h1.92 m³/h2.67 m³/hPipe SizeDN20DN25DN25Dimensions947*403*813mm940*393*1373mm940*393*1373mmNet Weight80Kg110kg110kgTesting Condition:
- Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C
- Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C
- Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C
- Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C
- Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant.