Business Type:
Manufacturer/Factory
Business Range:
Heat Pump, Water Source Heat Pump, Air Source Heat Pump, Water Heater, Swimming Pool Heat
Establishment:
2018
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Unique Flow Structure Design, Heat Exchange, Heat Transfer Performance manufacturer / supplier in China, offering Swimming Pool Heat Pump, Long Time Life Heat Pump Water Heater, Air Source Water Heater Circulation Standard Type of Heat Pump and so on.

1
    YRS
General Supplier
Supplier Homepage Consumer Electronics Water Heater & Components Heat Pump Water Heater China DC Variable Frequency Evi Cooling&Heating Water Unit

China DC Variable Frequency Evi Cooling&Heating Water Unit

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Energy Efficiency Grade: Two
Heat Temperature: 20-60ºC
Work Environment: Low-temperature Heat Pump

Dc variable frequency EVI technology is adopted for ultra-low temperature operation at -30ºC.
One machine to enjoy: winter heating + summer refrigeration;
Dc frequency conversion can achieve on-demand output, both fast heat and energy saving;
500 steps high precision electronic expansion valve, can adjust intelligently, and control accurately.

AHW series ( Dc variable frequency EVI Cooling&Heating Water Unit)ModelAHL05ANominal heating capacity (7 ºC)13.2kwNominal heating power consumption (7 ºC)3.69kWNominal heating COP (7 ° C)3.57Low-temperature nominal heating capacity (-12 ºC)10.6kWLow-temperature nominal heating power consumption (-12 ºC)4.00kWLow temperature nominal heating COP (-12 ºC)2.65IPLV(H)3Nominal cooling capacity (35 ° C)10.6kWNominal cooling power consumption (35 ºC)4.07kWNominal refrigeration EER (35 ° C)2.6Compressor typeDouble rotor / DC inverterInput power6.1KWNozzle sizeG1-1/''Amount of refrigerant / refrigerantR410A/3.2KgMake hot water temperature range20ºC~60ºCMake cold water temperature range10ºC~30ºCApplicable power supply220V/50Hzwaterproof levelIPX4Protection against electric shockIProduct Net Weight / Gross Weight145kgCrew noise≤60dB(A)Product net size1000*390*1385mmThe test conditions for the data in the table are as follows:
1. Nominal heating test conditions: Ambient air dry bulb temperature is 7 ºC, wet bulb temperature is 6 ºC, water inlet temperature is 40 ºC, water outlet temperature is 45 ºC;
2. Low-temperature heating test conditions: dry air temperature of ambient air -12 ºC, wet bulb temperature -14 ºC, water inlet temperature 36 ºC, water outlet temperature 41 ºC;
3. Nominal cooling capacity test conditions: Ambient air dry bulb temperature 35 ºC, wet bulb temperature 24 ºC, inlet water temperature 12 ºC, outlet water temperature 7 ºC;
4. As the products are continuously optimized and improved, the data in the table is subject to change without notice. Please refer to the product nameplate parameters.