Genuine manufacturer dc to ac inverter
Solar power inverter 1kw-3kw integrated MPPT charge controller
-- solar power inverter rated power: 1-3kw (off grid), higher power coming soon, and grid-tied units
-- solar power inverter, solar charger dc ac nominal: 12vdc/24vdc, 220vac, 110vac
-- home power inverter Ac charger: Max 70amp
-- solar power system, solar charge controller Pv charger(MPPT design): 45amp
-- solar system PV energy in priority for re-charge battery, or provide load in small load power
-- solar inverter with Ac charger will be activated when battery voltage low than 11vdc, ac will provide power for load
On condition that pv insufficient and battery exausted(10.3vdc per cell)
-- solar system Battery energy supply in priority means secure power backup solution.
Solar power system, solar inverter, solar power inverter, pure sine wave solar inverter enviromental, economic, power-saving application:
Home use for household electric appliance.
Solar battery charge controller specification:
Solar power inverter specification
Solar power inverter electrical view
Solar power inverter back view terminals block
Solar power inverter back view RS232 port
Solar power inverter battery cable accessory
ModelPV1012CPV1024CPV2012CPV2024CPV3012CPV3024CRated Output Power(W)100020003000 Line mode specificationsInput Voltage12V24V12V24V12V24VInput Frequency50Hz@40-80Hz/60Hz@40-80HzOutput Voltage WaveformPure Sine WaveOutput Short Circuit ProtectionCurrent limit (Fault after 10s) Inverter Mode SpecificationsOutput Voltage WaveformPure Sine WavePower Factor1Output Voltage (V)110Vac/120Vac/220Vac/230Vac ±10%Output Frequency (Hz)60Hz ± 0.3Hz / 50Hz ± 0.3Hz Auto Tracking Main Frequency Yes (Following main first connection) 50Hz @40-80Hz 60Hz @40-80HzOutput Voltage Regulation±10% rmsEfficiency>80%Over-Load Protection(110%<load<125%) ±10%: Fault (shutdown output) after 15 minutes; (125%<load<150%) ±10%: Fault (shutdown output) after 60s; Load>150 ±10%: Fault (shutdown output) after 20sSurge Rating3000VA6000VA9000VACapable Of Starting Electric Motor1HP1HP2HPInverter Breaker Size10A30ADC Input Voltage12V24V12V24V12V24VMin DC Start Voltage11V/22VLow Battery Alarm10.5Vdc ± 0.3Vdc for 12V battery 21.0Vdc ± 0.6Vdc for 24V batteryLow DC Input Shut-Down10.0Vdc ± 0.3Vdc for 12V battery 20.0Vdc ± 0.6Vdc for 24V batteryHigh DC Input Alarm & Fault16.0Vdc ± 0.3Vdc for 12V battery 32.0Vdc ± 0.6Vdc for 24V batteryHigh DC Input Recovery15.5Vdc ± 0.3Vdc for 12V battery 31.0Vdc ± 0.6Vdc for 24V batteryPower SaverLoad ≤25WCharger Mode SpecificationsInput Voltage110Vac/120Vac/220Vac/230VacInput Voltage Range96~127Vac/ 155~265VacOutput Voltage110Vac/120Vac/220Vac/230Vac ±10%Charge CurrentCharge Current RegulationCharge Current Adjustable: 25%, 50%, 75%, 100%. (Optional)Battery Initial Voltage0-15.7Vdc / 31.4Vdc (can operate with 0V battery)Charger Short Circuit ProtectionCircuit breakerOver Charge ProtectionBat. V ≥15.7Vdc/ 31.4Vdc , beeps 0.5s every 1s & fault after 60sGeneral SpecificationsCertificationCE / ISO9001Operating Temperature Range0°Cto 40°CStorage Temperature-15°C to Sheet3!C3 Operation Humidity5% to 95%Audible Noise60dB maxCoolingForced air, variable speed fanSize1012C / 1024C / 2012C / 2024C / 3012C / 3024C: 460x260x185MMGross Weight21KG26KG29.8KGMPPT solar controller functionRated voltage12/24V DCRated charge current 40ALoad current15AInput voltage range15-55V DCMax. PV open circuit array voltage55V DCTypical idle consumptionAt idle< 10mAOverload protection(DC load)2.0 * Inom>5s; 1.5 * Inom>20s; 1.25 * Inom temperature controlledBulk charge14.6V(default)29.2V(default)Floating charge13.4V(default)26.8V(default)Equalization charge14.0V(default)28.0V(default)Over charge disconnection 14.8V29.6VOver charge recovery13.6V27.2VOver discharge disconnection10.8V(default)21.6V(default)Over discharge reconnection12.3V24.6VTemperature compensation13.2mV/C26.4mV/CLead acid battery settingsAdjustableNiCad battery settingsAdjustableLoad control mode 1.Low Voltage Reconnect(LVR):Adjustable; 2.Low Voltage Disconnect(LVD):Automatic disconnection; 3.Reconnection:Includes warning flash before disconnect and reconnectionLow voltage reconnect12.0-14.0Vdc24.0-28.0Vdclow voltage disconnet10.5-12.5Vdc21.0-25.0VdcAmbient temperature0to 40°C(full load) 40-60°C(de-rating)AltitudeOperating5000m, Non-Operating 16000mProtection classIP21Battery temperature sensorBTS-optional remote battery temperature sensor for increased charging precisionTerminal size(fine/single wire)#8 AWG