Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Surge Protector, Lightning Arrester, Signal SPD manufacturer / supplier in China, offering 1000Mbps RJ45 Gigabit Poe Outdoor Lightning Protector, 100Mbps RJ45 Data Cat5 Single Channel Network SPD Surge Protector, Power Surge Protector Box/SPD Box/Instrument Protection Box and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Breaker & Protector Arrester China DC48V 100m 1000m Poe Surge Protection Devices for Ethernet Protection

China DC48V 100m 1000m Poe Surge Protection Devices for Ethernet Protection

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $20.00/ Pieces
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Opplei
Type: Signal Type Arrester
Structure: Valve Type Arrester
Installation: Parallel Arrester
Indoor RJ45 1000Mbps single channel Gigabit Power over Ethernet Surge protector
Model: SNH-RJ45/POE

APPLICATIONS:
Designed for Ethernet device not to be spoiled by lightning over-voltage, induced over-voltage and static discharge.
CAT6, CAT5e and CAT5 compatible
802.3af
10/100/1000 base-T Gigabit Ethernet protection
LAN, FDDI,CDDI, ATM,WLAN
PDH, SDH, SPDH
Industrial control
FEATURES:
Multi. Protection circuits, Gas-Tube + TVS technology
Dual protection in Common mode and differential mode
TVS array technology, low capacitance
Multi-Strike Capability
TECHNICAL PARAMETER: ModelSNH-RJ45/POEElectrical Parameter(Network & Power)Nominal operating voltage Un48VMax. continuous operating voltage Uc60VNominal discharge current(8/20µs)In3kAMax. discharge current (8/20µs)Imax5kALimiting voltage Up Line-line (@6kV, 10/700µs) ≤150VLine-line (@3kA, 8/20µs) ≤150VAdapt transmission rate1000MbpsInsertion loss≤0.5dBProtection line1-8Response time 1nsLoad current250mAApplicationCat. 6Mechanical characteristics Dimension28(H)x87(W)x100(L)mmWeight per unit120gProtection grade IP20Working conditionsTemperature: -40 to 85ºC,
Relative humidity: ≤95%Standards complianceCE, FCC, RoHS, ISO9001






INSTALLATION AND MAINTENANCEThe SPD should be connected in series between the protected device and the signal/power transmission channel.The input terminal (IN) of the SPD should connect to the signal/power transmission channel, and the output terminal (OUT) of the SPD should connect to the protected device.Connect earthing wire of the SPD to earthing bus-bar of the lightning protection system of the room or building.
No special duty needs to be carried out for maintenance. When problem arises and the SPD is suspected, check the system with SPD taken out of circuit. Should system recover, the SPD shall be regarded as a damaged unit and must be replaced immediately.