The product which is made up of 2 parts of Controller and transformer is a matched test equipment of light high-voltage transformer. It has superior performancefunctionality and access to reliablepleasing in appearanceeasy operation and maintenance.
The equipment shows the structure of box-type made from aluminum alloy. The equipment has simple alarm circuitreliable performance with time setting and synchronous sound and light alarm function.
Parameter of Controller:
1. Capacity: 5kVA
2. Input Voltage: AC220V 50/60Hz
3. Rated Input: 25A
4. Output Voltage: 0~250V
5. Power Output: 0~25A
6. Size: 530 x 430 x 330cm
7. Weight: GW/NW: 35kgs/26kgs
Parameter of Transformer:
1. Capacity: 5kVA
2. Input Voltage: AC220V 50/60Hz
3. Power Input: 25A
4. Output Voltage: AC100KV
5. Power Output: AC50mA
6. Transformer Ratio: 1000
7. Accuracy: <2%(F. S)
8. Size: 440 x 320 x 760cm
9. Weight: GW/NW: 78kgs/65kgs
Standard configuration of AC/DC Hipot set
1.Control unit....................................1 unit
2.Test Transformer............................1 unit
3.Power cable...................................1 unit
4.Test cables....................................1 set (5 pcs)
5.Earth wire......................................1 unit (6m)
6.Microamp meter............................1 unit
(It's not included if AC Hipot set)
7.Discharge rod................................1 unit
(It's not included if AC Hipot set)
8.Operating manual..........................1 unit
9.Calibration report...........................1 unit
2 Features
1)Direct reading: This equipment adopt digital LCD meter which can directly display HV voltage, meter voltage and LV current, HV current. It is easy for test observation and recording.
2)Accuracy measurement: Whole digital processing, built-in precise mathematical models, high test accuracy, precision test result.
3)Exactly protection function: Whole digital processing, over-current protection value setting, voltage setting, and over-voltage protection value setting all adopt digital display which makes the protection more exactly.
4)Automatically timing: This equipment has the timing function. It automatically measures time according to the set voltage which makes the timing more efficient.
Easy to carry: small size, light weight, the volume is 30%~ 70% the volume of the similar products.
Model (KVA/KV)InputOutputLVHVSize (mm)Weight (kg)3/50AC200V50kV15A60mA320x240x620405/5025A100mA360x255x6505410/5050A200mA410x285x7507215/50AC400V37.5A300mA440x290x7609320/5050A400mA450x300x77011030/5075A600mA480x320x80018050/50125A1000mA550x350x8402445/100AC200V100kV25A50mA460x350x11009510/10050A100mA490x350x112011615/100
AC400V37.5A150mA510x380x118016020/10050A200mA530x400x120018230/10075A300mA560x430x125020550/100125A500mA580x480x135022515/150150kV37.5A100mA630x500x165023520/15050A133mA640x510x168024030/15075A200mA650x540x171025550/150125A333mA660x550x175028520/200200kV50A100mA740x670x210030030/20075A150mA750x680x220035050/200125A250mA800x700x2250420