Product Description
Feature
Digital mammography x-ray breast diagnosis machine device price
Digital Mammography System
High voltage generatorTypeHigh frequency inverter typeX-ray tube voltage20-40kV(step 0.5kV)X-ray tube current10mA-160mAMaximum output power5kW(40kV,125mA)Nominal power4.8kW(30kV,160mA,0.1s)Radiograph time0.005-10smAs0.5mAS~560mAsMinimum mAs0.5mAs(50ms 10mA)Maximun mAs560mAsMinimum mAs in AEC6.3mAsExposure controlmanual ,semi-auto,autoRadiating modecross-ventilationX-ray tubeXM15HMT-113small focus/big focussmall focus/big focusFocus size0.1mm/0.3mm0.1mm/0.3mmMaximum anode heat capacity225kJ(300kHU)225kJ(300kHU)Maximum heat dissipation500W500WAnode cooling modeoil coolingoil coolingNominal voltage40kV40kVTarget angle15°10°/16°Target materialMoMoRadiation field18cm-50cm18cm-50cmInherent filtration0.5mmBe0.5mmBeAdditional filtration0.03mmMo/Anode speedlow-speed3000r/min; high-speed 10000r/minlow-speed3000r/min; high-speed 10000r/minAnode input power1.15-2KW / 4.8-9kW0.7-1.35kW / 2.9-4.9kWX-ray tube socket (C339v)Additional filtration0.03mmMoWeight13kgC Arm framevertical range of motion630-1400mm,deviation±5%Rotation range of motion+195°~-155°Angular division value 1°,deviation±2%FID660mm,deviation±5%3D tomographic axial rotation+30°~-30°deviation±2%Rotate Modepower-drive double speed rotatePreset angle and memory functionOppression platerange of motion245mm,deviation±10%range of motion in 1.5 times platfo150mm,deviation±10%range of motion in 1.8 times platfo75mm,deviation±10%Operation modeManual/AutoPressure range0-300N(Manual)150-200N(Auto)FPDAXS-2430HMD-2430Pixel unit85um85umEffective pixel size239.36*304.64mm239.36*304.64mmPixel matirx2816*3584 pixels2816*3584 pixelsSpatial resolution≥7 lp/mm≥7 lp/mmCooling modefan coolingfan coolingGrayscale≥16bit≥16bitDQE≥50%≥50%GridGrid proportion5:1Size338*264mmline pair36lp/cmfocus66cmCollimator (HMC-915)Power supply24V DC,2ARadiation fieldMin 5*5cm/Max 24*30cmRadiograph platformField 24*30cm SID 660mm,deviation±5%1.5 times radiograph platformField 16*20cm SID 440mm,deviation±5%1.8 times radiograph platformField 13.6*16.7cm SID 366.7mm,deviation±5%Inherent filtration0.02mmAlAdditional filtration0.03mmMo /0.025RhIllumination in max SID>160LuxTimerButton/Auto,30s timerIndicator lightLEDmaximum radiation leakage<40mRhLight field switchAutoWeight3.6kgImage Acquisition WorkstatScreen size/resolution19",Resolution 1280*1024,Contrat 1000:1Memory≥8GHard disk≥320GOSWin7Image formatDICOM3.0(can connect with RIS)Image storage capacity≥20000 imagesmamual input patients' date or download form HIS/RIS through DICOM WorklistCD-R writer (storage image)Choosing Breast implants FunctionIntegrated design with High voltage generator, exposure specification setting in workstation
Technical Parameters
mammography device
Radiation fieldMin 5*5cm/Max 24*30cm
TimerButton/Auto,30s timer
Related Products
Certifications
Our advantage
Our Company
Contact Amelia
Your inquiry very welcome!
We can accept small order,OEM order If you have any questions,you could contact me and we are willing to serve with you!