Double Conversion online UPS Inverter 1Kva/800W with 6 IEC 320 EN 60320 C13 Outlets1: True online Double Conversion UPS Inverter with 6 IEC Outlets and Long Backup time
2: UPS with Pure Sine Wave Output
3 Digital LCD Screen for UPS Display
4: UPS Output Power Factor 0.8
5: Using Eaton UPS tech, quality competitive with APC UPS and Santak UPS
UPS ApplicationQueen Star Series UPS 1-20KVA is specially designed for servers, data-center critical network devices, Sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
UPS Key Features1: Large Blue LCD digital display for UPS status and operation
2: Pure Sine Wave, Double Conversion Online
3: Wide input voltage range, Zero transfer time
4: Advanced MCU microprocessor control technology
5: Voltage regulator circuit
6: Comprehensive Electrical isolation and bypass protection
7: Input PF correction, reduce the harm of harmonic wave to the power grid, convenient to connect
with mini generator.
8: Input N/L Inspection function and date line protection
9: DC start when power off, convenient and reliable; Restart automatically when Electricity is restored.
10: Humanization bypass output, can be adjustable.
11: Smart RS232 communication with monitoring software
12: Protection against over voltage, over load, over current, over charge and so on.
Technical Specification
GREEN STAR onLINE UPS SELECtION GUIDEMODELG1K (L)G2K (L)G3K (L)PHASESingle phase with groundCAPACITY1000 VA / 800 W2000 VA / 1600 W3000 VA / 2400 WINPUTNominal Voltage100/110/115/120/127VAC or 200/208/220/230/240VACInput Voltage Range 55-145 VAC or 110-300 VAC Frequency Range 40Hz ~ 70 HzPower Factor>= 0.99 @ Nominal Voltage (100% load)OUTPUTOutput Voltage100/110/115/120/127VAC or 200/208/220/230/240VACVoltage Regulation ± 1%Frequency Range (Synchronized Range)47~ 53 Hz or 57 ~ 63 HzFrequency Range (Batt. Mode)50 Hz or 60Hz ± 0.1 HzCurrent Crest Ratio3:1Harmonic Distortion<= 3 % THD (Linear Load); <= 6 % THD (Non-linear Load)Transfer TimeAC to DCZeroInverter to Bypass4 ms (Typical)Waveform (Batt. Mode)Pure SinewaveEFFICIENCYTo AC Mode88%89%90%To Battery Mode83%87%88%BATTERYStandard ModelBattery Type12 V / 9 AH12 V / 7AH12 V / 7 AHNumbers266Typical Recharge Time4 hours recover to 90% capacityCharging Current (max.)1.0 ACharging Voltage27.4VDC ± 1%82.1 VDC ±1%82.1 VDC ±1%Long-run Model*Battery TypeDepending on the capacity of external batteriesNumbers368Charging Current (max.)1.0A/2.0A/4.0A/6.0 ACharging Voltage41.0VDC ± 1%82.1 VDC ±1%109.4VDC ±1%INDICATORSLCD
Load level, Battery level, AC mode,
Battery mode, Bypass mode, and Fault indicators
ALARMBattery ModeSounding every 4 secondsLow BatterySounding every secondOverloadSounding twice every secondFaultContinously soundingPHYSICALStandard ModelDimension, D x W x H (mm)397 X 145 X 220419X190x318Net Weight (kgs)132628Long-run Model*Dimension, D x W x H (mm)282 x 145 x 220397 X 145 X 220Net Weight (kgs)4.66.87.4ENVIRONMENTHumidity20-90 % RH @ 0- 40°C (non-condensing)Noise LevelLess than 50dBA @ 1 MeterMANAGEMENTSmart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MACOptional SNMPPower management from SNMP manager and web browser
* Long-run model is only available in 200/208/220/230/240VAC systems.