Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Flowmeter, Controller, Pump, Metering System
Establishment:
1999
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
North America, Europe, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

Metering System, Multi-Phase Flow Meter, Metering manufacturer / supplier in China, offering Customized Multi-Phase Flow Metering System (MPFM), Lzyn Coriolis Mass Flowmeter with Atex Pending, LYNSB Ultrasonic Flowmeter with Atex Pending and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Meter for Liquid & Gas Flow Meter China Double Rotator Flow Meter for Ship Yard with BV CCS

China Double Rotator Flow Meter for Ship Yard with BV CCS

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Shanghai, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Accuracy: ±0.2-0.5%
Main Application: Water, Wastewater, Diesel Fuel, Fuel Oil, Corrosive Liquid/Gas, High Viscosity Liquid
Size: Dn8mm -Dn400mm

LSZ- Double rotator flowmeter series Thermal Jacket


General
LSZ-Jacket flowmeter find extensive use in flow measuring appliations where process materials tends to become highly visous, solidify, or extract as line temperature drops, or where process fluids must be controlled at a specific temperature. Measurement is made while steam or hot oil is allowed to circulate through the jacked enclosure.

FeaturesSuperior accuracy to 0.1% of reading over 30:1 turn-downSelf-lubricating Very low noise and vibrationRugged double case construction prevents loss of calibration due to changes in pressure or temperatureNo oscillating, reciprocating or sliding parts or cranks to wear or disturb the balanced rotary action Field proven in precise tempering of the process fluid that tends to solidify, requiring heat retention.Flowmeter body is of pocketless design-an ideal construction for a jacketed flowmeter.A complete line of meter sizes, registers pulse generators, receiving instruments, etc. are available to meet widely varies

Construction and Liquid to be metered( Fullly Jacketed)

Sectional View
Description Liquids to be metered
Pocketless construction( transmission system: Magnetic coupling)
Max. operating pressure( pressure of fluid to be metered):1.18MPaBitumen, DMT, phthalic
Anhydride,
Naphthalene, etc.



Construction and Liquid to be metered( Standard Jacketed)
General SpecificationMeter body

ItemDescriptionNominal size mm08~400ConstructionDouble-case constructionApplicable fluidWater petroleum liquid foods chemical liquidsFlow rangeSee flow range tableOperating temp.range
++80~+150°C+150°C~+250°CAccuracy0.2%0.5%Repeatability0.067%0.167%MaterialsBodyCast steel or 304 stainless steel or 316 stainless steelRotorsCast steel or 304 stainless steel or 316 stainless steelBearingsCast steel or 304 stainless steel or 316 stainless steel



Register Specifications Model M1

ItemDescriptionMeter sizeRound Mechanical RegisterUnits IndicatedSterePointer RotationClockwiseLocal display(LCD)Cumulative totalizing counter0.1m3(std) 0.01m3 0.001m3Resettable counterNoInstantaneous flowrate0.01m3/h(std)Power supplyWithout output signalInstalled lithium batteryWith output signalExternal power source 24 VDCAmbient temperature-40°C ~ +70°CExplosionproof configurationNon-explosionproof typeExd II CT2~T6Degree of Protection for enclosureIP65

Note, output signal must matched with LPJ-I/F Photoelectric Pulse, then current signal or pulse signal could be chose


Model VR

ItemDescriptionMeter sizeSquare Mechanical RegisterUnits IndicatedStereLocal display(LCD)Cumulative totalizing counter0.1m3(std) 0.01m3 0.001m3Resettable counter0.1m3(std) 0.01m3 0.001m3Instantaneous flowrate NoPower supplyWithout output signalInstalled lithium batteryWith output signalExternal power source 24 VDCAmbient temperature-40°C ~ +70°CExplosionproof configurationNon-explosionproof typeExd II CT2~T6Degree of Protection for enclosureIP65

Note, output signal must matched with LPJ-I/F Photoelectric Pulse, then current signal or pulse signal could be chose
Main Technical ParametersTable:1

Nominal Dia. (mm)8~400Accuracy ±0.1%, ±0.2% and ±0.5%Pressure loss0~1000mPa.s<80Kpa 1000~20000mPa.2<150KPaNominal pressure1.6, 2.5, 4.0, 6.4 MPa Temperature range-20°C ~ +80°C +80°C ~ +150°C +150°C ~ +250°C Media viscosity0~20000mPa.s Ambient temperature-40°C ~ +70°CConnected flangeCan be custom-madePhotoelectric pulse(current)converterExd II CT6(Excluding acetylene)Electronic meterhead Exd II CT2-T6

Range of Flow
For Accuracy: 0.5% and 0.2%Table.2


Nominal
Dia.
(mm)Flow range m3/hPulse equivalent liter/pulse0.32-0.8mPa.s0.8-2mPa.s2-5mPa.s5-400mPa.s400-2000mPa.s2000-20000mPa.sGasoline/ liquefied gasKeroseneLight dieselCrude oil, heavy oilHi-viscosity
LiquidLiquid with high water content & super-high viscosity liquid0.5%0.2%0.5%0.2%0.5%0.2%0.5%0.2%0.5%0.2%0.5%0.2%150.6-3 0.4-4 0.4-4 0.4-4 0.3-2.4 0.3-2.4 0.001253-8 1.5-10 1-10 1-10 1-8 1-6
0.01
408-208-202.7-225.5-222.5-254.4-222.5-254.4-222.1-184.2-181.5-123-12509-3615-364.5-369-364-407.2-364-407.2-362.8-246-242.2-184.5-188020-8032-8010-8020-809-9016-809-9016-806.5-5614-565-4010-40


0.110025-10040-10013-10025-10012-12020-10012-12020-1008.5-7218-726.5-5414-5415055-22588-22031-25057-22525-25044-22025-25044-22018-15038-15012-10025-10020090-360150-36050-40090-36040-40072-36040-40072-36028-24053-21020-16040-160250135-540180-54068-540135-54060-600108-54060-600108-54042-36090-36030-24060-240300220-900300-900112-900225-900100-1000180-900100-1000180-90070-600150-60054-450113-450400400-1600550-1600200-1600400-1600180-1800320-1600180-800320-1600130-1100275-110090-750180-750

Double-Rotator Flowmeter
Accuracy: 0.1% Table.3


Nominal
Dia.
(mm)Flow range m3/hPulse equivalent liter/pulse0.32-2 mPa.s
2-5 mPa.s5-50mPa.s500-400 mPa.s400-2000 mPa.s2000-20000 mPa.sGasoline/ liquefied gasKeroseneLight dieselCrude oil,heavy oilHi-viscosity
LiquidLiquid with high water content & super-high viscosity liquid4011-229-227.5-227.5-227.5-224-123.3-100.0015018-3614.4-3612-3612-3612-367.5-226-180.018040-8032-8026.7-8026.7-8026.7-10016-4813-4010050-10040-10034-10034-10034-10024-7218-54150115-22090-22073-22073-22073-22040-12030-900.1200180-360144-360120-360120-360120-36060-18050-150250270-540216-540180-540180-540180-540100-30060-180300450-900360-900300-900300-900300-900200-600150-450400800-1600640-1600530-1600530-1600530-1600400-1200300-900

Double-Rotator Flowmeter-(Electron Meter head)
Accuracy: 0.5%, 0.2%Table. 4


Nominal
Dia.
(mm)Flow range m3/hPulse equivalent liter/pulse0.32-0.8mPa.s0.8-2mPa.s2-5mPa.s5-4mPa.s400-2000mPa.s2000-20000mPa.sGasoline/ liquefied gasKeroseneLight dieselCrude oil, heavy oilHi-viscosity
LiquidLiquid with high water content & super-high viscosity liquid0.50.20.50.20.50.20.50.20.50.20.50.20.0180.06-0.30.10-0.30.05-0.30.07-0.30.03-0.30.06-0.30.03-0.30.06-0.30.03-0.270.06-0.270.03-0.240.06-0.2415A0.2-0.80.27-0.80.1-10.2-10.1-1.50.1-10.1-1.50.1-10.1-0.80.16-0.80.08-0.70.15-0.715B0.25-10.33-10.25-1.50.25-10.25-30.3-30.3-30.4-30.1-1.50.2-1.50.1-1.20.2-1.2251.5-62-61.2-61.5-60.6-101.2-100.6-101.2-100.6-61.2-60.6-51.2-50.1

Double-Rotator Flowmeter-St. steel (-20°C ~ +80°C)
Accuracy: 0.5% and 0.2%Table.5

Nominal
Dia.
(mm)Range of flow m3/hPulse equivalent liter/pulse0.32-0.8 mPa.s0.8-2 mPa.s2-5 mPa.s5-400 mPa.s400-2000 mPa.s2000-20000 mPa.sGasoline/ liquefied gasKeroseneLight diesel, dieselCrude oil, heavy oilHi-viscosity
LiquidLiquid with high water content & super-high viscosity liquid0.50.20.50.20.50.20.50.20.50.20.50.2150.75-3 0.75-3 0.6-3 0.6-3 0.6-3 0.5-2.5 0.001252-8 2-8 1.6-8 1.6-8 1.2-6 1-5 406-248-246-248-244.8-
246-244.8-
246-243.6-
184-162.4-
122.5-100.01509-3612-369-3612-367.2-
369-367.2-
369-364.8-
245.5-
223.6-
184-168020-8027-8020-8027-8016-8020-8016-8020-8012-5612-488-409-360.110025-
10034-
10025-
10034-
10020-
10025-
10020-
10025-
10015-7515-6011-5411-4515055-
22075-
22055-
22075-
22045-
22055-
22045-
22055-
22030-
15035-
13520-
10023-9020090-
360120-
36090-
360120-
36072-
36090-
36072-
36090-
36043-
21050-
20032-
16038-150250135-
540180-
540135-
540180-
540108-
540135-
540108-
540135-
54072-
36090-
36048-
24060-240300225-
900300-
900225-
900300-
900180-
900225-
900180-
900225-
900120-
600150-
60090-
450113-450

Double-Rotator Flowmeter-St. steel high temp. type (+80°C ~ +150°C)
Accuracy: 0.5, 0.2Table.6

Nominal
Dia.
(mm)Range of flow m3/hPulse equivalent liter/pulse2-5 mPa.s5-50 mPa.s50-400 mPa.s400-2000 mPa.s2000-20000 mPa.sLight dieselCrude oil, heavy oilCrude oil, heavy oilHi-viscosity
LiquidLiquid with high water content& super-high viscosity liquid0.50.20.50.20.50.20.50.20.50.2405.6-
22.57-205.6-
22.57-205.6-
22.57-204-154-123-123.5-100.01509-3610-329-3610-329-3610-324.5-227-204.5-186-188020-8025-7520-8025-7520-8025-7512-4813-409-3610-30

0.110025-
10030-9025-
10030-9025-
10030-9015-6017-5011-4514-4015045-
22075-
22045-
22075-
22045-
22075-
22035-
13534-
10023-9027-8020090-
360120-
36090-
360120-
36090-
360120-
36050-
20054-
16038-15043-130250135-
540180-
540135-
540180-5
40135-
540180-
54090-
360120-
36060-24080-240300225-
900300-
900225-
900300-
900225-
900300-
900150-
600200-
600113-450150-450

Double-Rotator Flowmeter-St. steel high temp. type (+150°C ~ +250°C)
Accuracy: 0.5% and 0.2%Table.7


Nominal
Dia.
(mm)Range of flow m3/hPulse equivalent liter/pulse2-5 mPa.s5-50 mPa.s50-400 mPa.s400-2000 mPa.s2000-20000 mPa.sLight dieselCrude oil, heavy oilCrude oil, heavy oilHi-viscosity
LiquidLiquid with high water content& super-high viscosity liquid0.50.20.50.20.50.20.50.20.50.2407.5-22.510-207.5-22.510-207.5-22.510-205-156-124-125-100.015012-3616-3212-3616-3212-3616-327.5-
22.510-206-189-188026.7-8035-7526.7-8035-7526.7-8035-7516-4820-4012-3615-30
0.110034-
10045-9034-
10045-9034-
10045-9020-6025-5015-4520-4015075-
220110-
22075-
220110-
22075-
220110-
22045-13550-10030-9040-80200120-
360180-
360120-
360180-
360120-
360180-
36065-
20080-
16050-
15065-130


Double-Rotator Flowmeter-Carbon steel high temp. type (+150°C ~ +250°C)
Accuracy: 0.5, 0.2 Table.8

Nominal
Dia.
(mm)Range of flow m3/hPulse equivalent liter/pulse2-5 mPa.s5-50 mPa.s50-400 mPa.s400-2000 mPa.s2000-20000 mPa.sLight dieselCrude oil, heavy oilCrude oil, heavy oilHi-viscosity
LiquidLiquid with high water content& super-high viscosity liquid0.50.20.50.20.50.20.50.20.50.2404.5-22.55.6-22.54.5-22.55.6-22.54.5-22.55.6-22.54.2-185-153-124-120.01507.2-369-367.2-
369-367.2-
369-366-247.5-
22.54.5-
185.5-17.58016-8020-8016-8020-8016-8020-8014-5616-4810-4012-360.110020-10025-10020-10025-10020-10025-10018-7220-6014-5416-4815045-22055-22045-22055-22045-22055-22038-15045-13525-10030-9020072-36090-36072-36090-36072-36090-36053-21065-20040-16050-150250108-540135-540108-540135-540108-540135-54072-36090-36060-24080-240300180-900225-900180-900225-900180-900225-900120-600150-600113-450150-450

Note: The flowmeter is also suitable for interim measurement during installing/uninstalling and ship installing.
Applications:
Why Yinuo
(1) For electronic products, we have automatic chip mounter (SMT) production line and high/low temp. testing equipment.
(2) For mechanical products, we have advantage on casting, machining, and welding which is the key point in eyes of Russian.
(3) For calibration, we have calibration facilities approved by China government for oil, water and gas.
(4) For flowmeter, we are Top leaders in China for both of Coriolis Mass Flowmeter & PD flowmeter, which be approved the UL, CE, CCS (China) and BV certificate (France) for marine market.
(5) For pump, we combined Russian military technology with China low cost to manufacture for large capacity transportation of oil, chemical, water, and wastewater even if contain some participles and we also design and produce twin-screw pump for high pressure, high viscosity liquid with multiphase.
(6) For SCADA loading & metering/ Skid Mount System, we also have much experience in China and in Afghanistan, Equatorial Guinea and are trying to promote in all over the world.

FAQ.
1.Customer: What's the delivery date?
YINUO : Our stock is based on GB/DIN flange, and the delivery date for it is 10 days; we also accept the other flanges like ANSI/JIS or thread connection, and the delivery date is 15 days.;
2.Customer: Could you design according to my requirements?
YINUO : Yes, we could provide OEM service.
3. Customer: What's the warranty period?
YINUO : Our warranty period is 12 months after installation but not longer than 18 months after the shipment.