Data Logger, Temperature Recorder, Temperature Data Logger manufacturer / supplier in China, offering Pdf Single Use Temperature Data Logger, Pdf Temperature and Humidity Data Logger with LCD, Ec-770 F/N Coating Thickness Gauge 1~3% Accuracy 1500um 5000um and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | Contact Supplier |
Local Area: | Shenzhen, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Measuring Range: | 0 to 1500um |
---|---|
Accuracy: | ±(3%+1um) |
Resolution: | 0~99.9um(0.1um), Others(1um) |
These compact gauges can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous
metals.
Features:
· High accuracy and stability
· LCD shows number, mean, maximum, minimum
· Easy to do zero calibration
· Power off automatically
· Low battery indication
· Detect the substrates type automatically
Specifications:
Model
EC-550A
Probe
F-Probe & N-Probe
Measuring Principle
Magnetic induction & Eddy Currents
Measuring Range
0 to 1500 um
Accuracy
± (3%+1 um)
Resolution
0~99.9um(0.1um), others(1um)
Calibration
One point to four points calibration, zero point calibration
Statistics
No. of readings, mean, minimum, maximum and standard deviation
Units
um, mm, mil
Alarm
User can set the high/low alarm limit; Alarm icon displayed on LCD when over the limit
Minimum Curvature Radius Convex
1.5 mm
Minimum Curvature Radius Concave
25 mm
Minimum Measuring Area
Diameter 6 mm
Minimum Thickness Of Substrate
F-probe: 0.5 mm(0.02");N-probe: 0.3 mm(0.012")
Computer Interface
Download data via USB
Power Supply
Two 1.5 V AAA battery
Operation Environment
Temperature: -10 to 50ºC
Storage Environment
Temperature: -10 to 60°C(-4 to 158°F)
Standard Certification
CE, ROHS, ISO 2178, 2360, GB/T 4956-2003, 4957-2003
Dimensions
116mmX53mmX24mm, 80g(int. probe)/144g(ext. probe), ABS
1. OEM Manufacturing
2. ODM service
3.Small order/ prompt delivery
4.We will reply to you for your inquiry within 24 hours.
Why choose us?
1. Our quality control team will inspect every process from material purchase to final products. Our defective rate is about 0.1%.
2. Standardized work flows guarantee quality
3. 100% tested before delivery, almost zero complaint.
4. High quality product with competitive price
5. We have a team full of passion and creativity, continuous innovative design makes us leading the industry.
6. 10 years' experience in R&D and manufacturing.
7. Strong R&D term supports perfect customized projects.
8. Stable delivery date.
9. Excellent after-sales service.
1. Is the measuring error large?
• Enter the menu interface, clear the calibration data; shut down torestore the factory configuration steps; do zero calibration after booting, (Note: you need to dozero calibration on the customer's own substrate)
2. Does the measurement screen display overflow?
•The coating thickness exceeds the measurement range.
•There is an error and zero calibration is required on the substrate.
•Probe fault
3. Measurement no response?
•Check if the battery has power.
•The probe has a fault.
•Whether the measured material meets the measurement principle.
4. Does the measurement show a negative number?
•It is judged according to the customer's materials whether the machine accuracy is applicable.
•The calibration did not do well and needs to be recalibrated.
5. During the measurement process, is it sometimes display F, sometimes display N?
• The automatic mode undistinguishable the type of material and it requires manual switching of the measurement principle.
6. How to do calibration?
•Please refer to the zero calibration, point calibration step.
7. Long press "ZERO" does not respond?
• You need to restore the factory settings and then operate.
8. It can measurement but there is no reading, why?
•Confirm whether the mode is in continuous measurement mode
•Check if the beep is broken