Business Type:
Manufacturer/Factory
Business Range:
Electromagnetic Water Meter, Electromagnetic Flow Meter
Establishment:
2011
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Conductivity Probe, Electrical Conductivity Sensor, Water Conductivity Sensor manufacturer / supplier in China, offering High Quality Online Industrial Digital Conductivity Sensor, Double-Head Integral Type Electromagnetic Flow Meter, Stainless Steel Magnetic Beer/Water/Milk Sanitary Electromagnetic Flow Meter for Brewery and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Meter for Liquid & Gas Flow Meter China Electromagnetic Flow Meter for Cement Slurry Magnetic Flowmeter

China Electromagnetic Flow Meter for Cement Slurry Magnetic Flowmeter

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $4000.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Accuracy: 0.3%/0.5%/1%
Main Application: Water, Wastewater, Corrosive Liquid/Gas, Serous Fluid
Size: DN15-500
Electromagnetic Flow Meter for Cement Slurry Magnetic Flowmeter
DGS-006 series electromagnetic flowmeter is designed specifically for the flow measurement of large - wear fluid, such as cement slurry. The structural features of the sensor and the special performance of the converter fully meet the requirements of the flow measurement of the cement slurry.
DGS-006 is preferred to measure slurry fluid such as pulp, mud, and coal-water slurry. With high frequency switching excitation and proprietary slurry-noise reduction technology, DGS-006 can accurately measure the flow of slurry fluid with good stability.

The key technology to measure slurry fluid is to remove the slurry-noise and recover real flow signal from complicated noise signal. based on slurry fluid mathematical models and signal processing technique, raw signals are processed and real flow signals are recovered.
Difficulties in the composition and measurement of cement slurry:
1.The cement slurry contains a large amount of solid particles and friction electrode, resulting in "spike pulse interference", which causes great fluctuations in the measurement of the flowmeter
2.Flow fluctuation caused by the pulsation of the pressure pump (such as the screw pump, diaphragm pump and piston pump);
3.After the fluid stops flowing, the electrode and the inner lining will adhere to the cement slurry
4.The serious wear of the coal slurry to the lining and electrode of the electromagnetic flowmeter is also a difficult point for the designers.

Factors that cause fluctuations in the flow of coal-water slurryApplicabilitySolutionOther solutionsWhen the solid particles of the cement slurry are rubbed through the surface of the electrode, the contact electrochemical potential of the electrode surface suddenly changes, resulting in the "spike pulse interference" of the electrode detected by the sensor output.√The sensors with special materials and structure and special transducers.
/The pulsation caused by the pulsating flow of the pump at different speedsxThe true fluctuation of flow, the flow meter can't solve.
.Lengthening the front straight section of the flowmeter is the best way to solve the pulsation caused by the work of the coal slurry pressurization pumpThe pulsating flow (6%~15%) caused by the pump.xThe cement adheres to the electrode√After discharge pressure, take out the electrode (removable electrode), clean it and install it again.

Distinctive advantages:
√ No pressure loss, the measurement is not affected by temperature, pressure and other changes.
√ It is very convenient to replace the electrode of the flow meter without cutting the flowmeter shell.
√ Anti-scour lining protection ring designed with flow meter inlet
√ Wear-resistant tungsten carbide electrode
√ Ceramic lining, especially wear-resistant
√ Anti-"Spray spike interference" algorithm and using 75Hz high frequency switching excitation method,The flow measurement is stable and the fluctuation is very small
√ The signal -to -noise of the output signal of the sensor electrode is more than 3 times higher than that of the conventional flowmeter
√ Excellent low velocity performance
√ Both the power supply and the output circuit adopt reliable lightning protection and surge protection, with high reliability and low fault.
√ Reliable detection technology of empty pipe
Performance parameters
Precision of electromagnetic flowmeter:

Flow rate rangeDGS-006 electromagnetic flowmeter1.0m/s to 5m/s0.25% of rate0.3m/s to 1.0m/s0.5% of rate<0.3m/s±0.015m/s


1. Repeatability: ±0.1% of measured value
2. Response time: the maximum 0.3 milliseconds relative to the input change.
3. Stability: the stability over 6 months is ±0.1% of measured value
4. Impact of ambient temperature: ±0.25% over operating temperature range
5. Impact of the installation location: the installation is not affected as long as the sensor can be fully charged and enough straight sections are ensured before and after
6. Startup time: it takes 50 milliseconds to start from zero flow
7. Preheating time: it takes 15 minutes from power supply to rated measurement accuracy
Sensor parameters:

Nominal diameter1 inch to 20 inch ( DN15 to DN500 )Temperature range of the measured fluid-29 to 80ºCBody materialSUS304 stainless steelFlange material and shellcarbon steel, SUS304 stainless steel (optional)Shell coatinganti-corrosion polyester paintLining materialceramic liningElectrode materialTungsten carbide electrode (detachable) Process connectionPN1.6mPa to PN25mPaLining protection ring316 manganese chromium alloSensor protection levelIP65,IP68


Converter parameters:

Ambient temperature range- 20 to 149 of (- 29 to 65 ºC)Shell materiallow copper die-casting aluminum Nema 4X ,IEC60529 IP66 (standard), or stainless steel material converter shellPowerAC 86 to 265V, 50/60HZ, 1A fast fuse insurance; DC 16V to 36V, 1A fast fuse insurance Output4-20 mA output, pulse or frequency outputCommunication protocolRS485 communication, Hart protocol can be selectedProtection level IP65/IP68Correction5-segment nonlinear correctionLCD displayshowing instantaneous flow, total volume, flow rate, etc.
Excitation methodSpecial high voltage frequency excitation modePower15 watts


Flow range:

Our company:

FAQ:


How is the flow meter warranty?

We could provide 12 months warranty for your flow meter .

Could you provide me the shortest lead time?

Our shortest lead time is 5~7 days after your payment.

How to pay for that ?

Of course we could accept T/T, Paypal, Trade Assurance Order, Western Union, you will get full protection for your orders.

Do you accept OEM?

Yes, we accept OEM.

How to deal with the after-sales?

We have 1-year-warranty with 24/7 on-line support and video technical support. If the flowmeter can't work in 6 Months, we can send you a new flowmeter.