Electronic Hygrostat Adjustable and pre-set relative humidity Temperature-compensated NTL 77-M (NTL 77)
• Adjustable and pre-set relative humidity
• Status indicator (LED)
• High switching capacity
• Clip fxing
• Temperature-compensated
The electronic hygrostat senses the relative humidity in an enclosure with electric/electronic components and turns
on a heater at the set point, helping prevent the formation of condensation in the enclosure. The LED integrated in the
adjustment knob is lit when the connected heater is in operation.
Technical DataCERoHSISO9001Patent
NTL 77-M (NTL 77)Switch difference5% RH (±3% RH tolerance) at +25°C (+77°F), 50% RHReaction time 5 sec.Contact type change-over contact (relay)Service life> 50,000 cyclesMax. switching capacity (relay output)240VAC / 120VAC 8 (1.6) AMax. inrush current AC 16A for 10 sec.Optical indicatorLEDConnection5-pole terminal, clamping torque 0.5Nm max.: rigid/stranded wire 2.5mm² (AWG 14)Mountingclip for 35mm DIN rail, EN 60715Casing plastic according to UL94 V-0, light greyDimensions 64.5 x 42.5 x 38mmWeightapprox. 70gFitting positionFitting positionOperating/Storage temperature 0 to +60°C (+32 to +140°F) / -20 to +70°C (-4 to +158°F)Operating/Storage humiditymax. 90% RH (non-condensing)Protection type IP20
¹ When connecting with stranded wires, wire end ferrules must be used.
Examples of connection