Business Type:
Trading Company
Business Range:
Medical Equipment, Anesthesia, Monitor, X-Ray, Lab
Establishment:
2003
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T
Main Markets:
South America, Europe, Southeast Asia, Middle East, Africa
OEM/ODM Service
Sample Available

Ventilator Machine, Ventilator, ICU Ventilator Machine manufacturer / supplier in China, offering Ventilator Machine with Air Compressor for ICU, Medical IV Drug Ambulance Infusion Pump Machine with Drop Sensor, Movable Stainless Steel Cuna Lit Bebe Hospital Baby Cot Infant Crib Bed and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Surgical Equipment China Emergency Defibrillator Monitor Medical Equipment PT-9000c

China Emergency Defibrillator Monitor Medical Equipment PT-9000c

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Hanzhong, Shaanxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Type: Defibrillator
Certification: CE
Sine Wave: Monophasic Technology/Biphasic Technology(Optional
DefibrillatorDefibrillator type: Manual, Synchronized, Asynchronized
Output wave form: Monophasic technology/Biphasic technology(optional)
Energy accuracy: <+1%
Charging time: At 360J less than 10sec
Standard Adult/Pediatric Paddles: Reusable external adult paddles(pediatric paddles intergrated)
Power: AC and internal NIMH battery
Energy Selection; 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 Joule (nominal at a resistance of 50)
ECGECG lead: I, II, III, a VR, a VL, a VF, V1-V6, GND
S-T segment analysis: 2.0-2.0mv
Protegtion: Withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.
Arrhythmia analysis; Yes
NIBPMethod: Automatic oscillation
Working mode: Manual/automatic/stat(5 minutes)
Measur: Adult: 10-250mmHg
Ement: Pediatric: 10-200mmHg
Rabge: Neonatal: 10-135mmHg
TEMPMeasurement range: 20-45° C
Resoluion: 0.1° C
SpO2Display: SpO2 value, pulse histongram, waveform, pulse
Range: 0-99% for adult, pediatric and neonatal patients
Probe: Stand: Adult finger clip Optional: Pediatric Y-type clip and neonatal wrap
PulsePulse range: 0-255bpm
Pulse accuracy: ± 2bpm
DisplayLED Dimensions: 7" diagonal(155mm*88mm)
Type: High resolution true-color graphic LED
Resolution; 480*234

DefibrillatorDefibrillator type: Manual,Synchronized,AsynchronizedOutput wave form: monophasic technology/Biphasic technology(optional)Energy accuracy: <+1%Charging time: at 360J less than 10secStandard Adult/Pediatric Paddles: reusable external adult paddles(pediatric paddles intergrated)Power: AC and internal NIMH batteryEnergy Selection;0,3,5,7,10,20,30,50,100,200,300,360 Joule (nominal at a resistance of 50)ECGECG lead: I,II,III, a VR, a VL, a VF, V1-V6,GNDS-T segment analysis: –2.0-2.0mvProtegtion: withstand 4000v AV/50HZ voltage in isolation and work against electrosurgical interence and defibrillation.Arrhythmia analysis; yesNIBPMethod: automatic oscillationWorking mode: manual/automatic/stat(5 minutes)Measur: adult: 10-250mmHgEment: pediatric: 10-200mmHgRabge: neonatal: 10-135mmHgTEMPMeasurement range: 20-45°CResoluion: 0.1°CSpO2Display: SpO2 value, pulse histongram, waveform, pulseRange: 0-99% for adult, pediatric and neonatal patientsProbe: stand: adult finger clip Optional: pediatric Y-type clip and neonatal wrapPulsePulse range: 0-255bpmPulse accuracy: ±2bpmDisplayLED Dimensions:7" diagonal(155mm*88mm)Type: High resolution true-color graphic LEDResolution;480*234