Brine to Water Heat Pump, Water to Water Heat Pump, Geothermal Heat Pump manufacturer / supplier in China, offering Brine to Water Heat Pump with Copeland Compressor and R410A Refrigerant, Water to Water Heat Pump, Geothermal Heat Pump, Swimming Pool Heat Pump Water Heater with High Component (SP05P-E5), Large Air Source Heat Pump with Long Warrenty Hw60p ( and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $13500.00/ Piece |
Local Area: | Jiaxing, Zhejiang, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T |
Energy Efficiency Grade: | One |
---|---|
Heat Temperature: | 40-60°c |
Work Environment: | Common Heat Pump |
* Copeland compressor & R410a / R407c refrigerant;* Stainless steel 304 for all fasteners, for side covers of evaporator;* Preservative oil for copper tubes and all important part of cabinet;* Chinese No.1 brand "ND" shell & tube heat exchanger;* Japan "Saginomiya" or "Sanhua" electronic expansion valve;* "Sanhua" 4-way valve;* "Schneider" AC contactor & Relay* KonNEN LCD controller;* Delivery time: 25~30 days;* Payment term: T/T 30% in advance and T/T 70% before delivery;* Warranty time: 24 months after delivery.
D03 series( EVI Air source heat pump Hot water use & Space heating) EVI-150307 EFH3P-S5EFH5P-S5EFH10P-C24EFH14P-C24EFH20P-C48EFH30P-C48EFH48P-C96Normal conditionHeating capacitykW12 19 36 50 75 105 165 Input powerkW2.80 4.40 8.20 11.57 17.10 24.10 38.10 Input currentA5.30 8.60 14.80 23.86 33.00 45.10 72.30 COP/4.29 4.32 4.39 4.32 4.39 4.36 4.33 Nominal conditionRated heating capacitykW9.50 15.00 42.00 30.00 60.00 90.00 144.00 Rated input powerkW2.60 4.10 8.10 11.39 16.10 24.50 39.30 Rated input currentA5.20 8.20 15.30 21.56 30.20 46.00 73.60 COP/3.65 3.66 3.70 3.68 3.73 3.67 3.66 Low temperature conditionHeating capacitykW5.50 8.80 17.50 24.50 36.50 52.50 84.00 Input powerkW2.26 3.65 7.30 10.21 15.10 21.60 34.90 Input currentA4.29 6.93 13.00 18.30 28.10 40.80 65.70 COP/2.43 2.41 2.40 2.40 2.42 2.43 2.41 Space heating standard conditionsheating capacitykW9.00 14.50 28.80 40.32 57.50 86.25 138.00 Input powerkW2.82 4.61 9.20 12.80 18.30 27.45 43.92 Input currentA5.33 8.71 17.40 24.36 34.80 52.20 83.50 COP/3.19 3.15 3.14 3.15 3.14 3.14 3.14 Maximum input power/currentkW/A3.61/6.925.71/11.2010.62/20.7514.86/29.0522.27/43.3631.38/61.251.5/100.3Rated hot water output temperatureºC55Rated space heating water output temperatureºC45Maximum hot water output temperatureºC60Rated hot water produce capacityL/H204.25322.5645903129019353096Power supply3N 380V/50HzCompressorTypeFully closed scroll typeStart modeDirectly startWater side heat exchangerTypeShell & coil(tube) heat exchangerWater flowM3/h2.1 6.0 8.9 12.9 18.0 29.9 Water pressure dropKPa≤50≤60≤60≤65≤65≤65Pipe sizeDN253232506580Middle heat exchangerTypeBrazed plate type heat exchangerProtections1. High pressure and low pressure protection,
2. Anti-freezing protection,
3. High temperature protection,
4. Too big of the water temperature difference for outlet and inlet protection,
5. Overload protection,
6. Lack phase protection,
7. Reverse phase protection, etc.. NoiseDB(A)≤55≤65≤68≤70≤73≤78Unit dimensionsmm835x410x13301000x1000x18582050x1000x19802050x2000x1980Package Sizemm980*550*15501150*1150*22502200x1150x23002300x2100x2300WeightKG1151753554256208551300Testing condition: 1. Normal condition: dry bulb 20ºC, wet bulb 15ºC; initial water temperature 15ºC, end water temperature 55ºC.
2. Nominal condition: dry bulb 7ºC, wet bulb 6ºC; initial water temperature 9ºC, end water temperature 55ºC.
3. Low temperature condition: dry bulb -12ºC, wet bulb -14ºC; initial water temperature 9ºC, end water temperature 55ºC.
4.Heating standard condition: dry bulb temperature 7ºC, wet bulb temperature 6ºC; Cold water inlet temperature 40ºC,outlet water temperature 45ºC.
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product lable when buy, or refer to us for any information. Our company keeps the right to interpret.