Business Type:
Manufacturer/Factory
Business Range:
Oil Machine, Oil Press Machine, Oil Extraction Machine, Oil Refining Machine, Palm Oil ..
Establishment:
2004
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion
Main Markets:
South America, Africa, Others
OEM/ODM Service
Sample Available

Oil Pressers, Oil Pressing Machine, Press Machine manufacturer / supplier in China, offering Fully-Automaticrefining Soybean Oil Pressers/Soybean Oil Pressing Machine/Sunflower Oil Refining Machine, Mini Vegetable Oil Refining Machine, Small Oil Refining Machine, Peanut Oil Making Machine, Groundnut Oil Pressing Machine and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Disinfect Equipment & Sterilizer China Factory Eto Gas Sterilizer Ethylene Oxide Sterilization Equipment

China Factory Eto Gas Sterilizer Ethylene Oxide Sterilization Equipment

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $100000.00/ Piece
Local Area: Xian, Shaanxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion
Theory: Pneumatic
Type: Gas Sterilization Equipments
Certification: CE
Ethylene Oxide Sterilizer Machine Manufacturer
Description of ethylene oxide sterilizer
The range of large-scale HTAJ3 ethylene oxide sterilizer is a kind of low-temperature sterilization equipment: This product is designed by using advanced computer technology, automation technology, welding technology and process on the basis of absorbing the advantages of similar products at home and abroad.
Precautions
(1) Installation requirements of ethylene oxide sterilizer: The ethylene oxide sterilizer must be placed in a well-ventilated place, and it must not be placed near a fire source. In order to facilitate repair and regular maintenance, 51cm space should be reserved on each side (including the top) of the ethylene oxide sterilizer. Special exhaust pipes should be installed and completely isolated from other exhaust pipes of the building.
(2) Ethylene oxide safety protection principles and precautions:
1) Keep ethylene oxide sterilizers and cylinders or cans away from sources of ignition and static electricity.
2) Ethylene oxide storage should be free of ignition sources, no rotating motor, no sun, good ventilation, and the temperature is lower than 40 ºC, but it should not be placed in the refrigerator. Dispose of in strict accordance with the relevant national storage requirements for flammable and explosive materials.
3) Do not use too much force when administering or opening the bottle, so as not to spray the liquid.
4) Monitor the air concentration of the ethylene oxide working environment every year.
5) Ethylene oxide staff should be trained in expertise and emergency management.

Product formsHTAJ3 manual door cabinetPower sourceAC380V,50HzSterilizer size(Length x width x height): 2600x1400x1400mmSterilizer volume3 m³Sterilizer interior material304 Anticorrosive stainless steelOuter carton materialCarbon steelTemperature during sterilization50ºC ±3ºCWorking pressure-60kpaMaximum anti-stress value-150kpaHumidity during sterilization45%-75% Pressure sensorThe built-in pressure sensor automatically detects the pressure inside the cavity to ensure that the pressure in the cavity is accurate and effective.Ethylene oxide sterilization concentration1g/L AdjustableLeakage rate of sterilization chamberThe leakage rate is measured under the conditions of no-load and constant temperature in the sterilization chamber, the test pressure is -50kPa, and the measurement time is 1h. The average leakage rate within the measurement time is ≤0.16kPa / min.Sterilization time0-99 hours AdjustableVacuum speed15-25 minutes to -60kpaAir replacementAutomatic ventilation, ventilation times and interval time can be set freelyAutomatic control systemOne-key start to end, the whole process of automatic completion with printing recordsDisplay statusDisplay temperature, humidity, pressure, sterilization time, residual gas treatment time, frequency
PrinterRecord and print the sterilization information of the whole process for verification.Humidity sensorThe built-in humidity sensor automatically detects the humidity in the cavity to ensure that the humidity in the cavity is not less than 45% RH.Residual gas treatment deviceThe removal rate of the filter with a particle diameter ≥ 0.3 μm is not less than 99.5%.Temperature sensorThe built-in temperature sensor automatically detects the temperature in the cavity to ensure that the temperature in the cavity is maintained within an accurate range of 50 ° C ± 3 ° C.Humidification systemPulse humidification under vacuum to ensure that the humidity in the cavity is uniform and controllable; the humidity in the sterilization chamber should be controlled within the range of relative humidity 45% -80%;alarm systemHigh temperature alarm system, ultra-low pressure alarm system; When the sterilization temperature of sterilization chamber exceeds 59ºC, the alarm shall be audible.Vacuum rateUnder no-load condition, the time for the sterilization cabinet to vacuum from atmospheric pressure to -60kpa should be ≤30min.Vacuum systemThe use of oil-free vacuum pump, simple and convenient, fast vacuum rate, long service life.Multiple protection functionsWith over - pressure and over - temperature protection function, more safe and reliable.Heating systemAdopt explosion-proof electric heating device, more convenient and fast


Technical characteristics

HTY series ethylene oxide sterilizer is a special equipment for low-temperature fumigation and sterilization of articles sealed in the sterilization room under a certain temperature, pressure, humidity and a certain action time with the mixture of pure ethylene oxide and ethylene oxide. Ethylene oxide gas is a very active chemical disinfectant, which can not only achieve broad-spectrum sterilization, but also achieve a reliable sterilization effect.
Advantages of ethylene oxide sterilizer
Simple operation: one-button operation, microcomputer control, simple and convenient, digital display of sterilization process. Print records: Record and print sterilization information for sterilization process, which is convenient for verification and archiving. Filtration system: The air inlet is equipped with a filtration system, which can effectively filter out germs and microorganisms and avoid secondary pollution during exhaustion.(1)Installation requirements of ethylene oxide sterilizer:
1)The ethylene oxide sterilizer must be placed in a well-ventilated place, and it must not be placed near a fire source.
2)In order to facilitate repair and regular maintenance, 51cm space should be reserved on each side (including the top) of the ethylene oxide sterilizer.
3)Special exhaust pipes should be installed and completely isolated from other exhaust pipes of the building.
(2)Ethylene oxide safety protection principles and precautions:1) Keep ethylene oxide sterilizers and cylinders or cans away from sources of ignition and static electricity. 2) Ethylene oxide storage should be free of ignition sources, no rotating motor, no sun, good ventilation, and the temperature is lower than 40 ºC, but it should not be placed in the refrigerator. Dispose of in strict accordance with the relevant national storage requirements for flammable and explosive materials. 3) Do not use too much force when administering or opening the bottle, so as not to spray the liquid. 4)Monitor the air concentration of the ethylene oxide working environment every year. 5)Ethylene oxide staff should be trained in expertise and emergency management.
company information
The Group relies on aggregating professionals in the field of medical equipment, concentrated technical forces to invest in research and development, and rapidly rises in the medical field. With great investment in research and development and innovation, the company has achieved a series of results in the related fields of ethylene oxide sterilizers. Combined with the 5G intelligent AI platform to realize the intelligent operation of the equipment, the simplicity, safety, and sterilization effect exceed the customer's requirements. We always treat our customers with a high standard and a responsible attitude. The corporate philosophy of being a person first, and then acting, has laid a solid foundation for the group company to deepen its cultivation in the medical device industry.
Our equipment meet CE standard, ISO11135 and EN1422 that can be widely used for sterilizing medical device, healthcare facilities, plastic and disposible products, Spice, traditional Chinese medicinal materials, culture goods, and currency, etc.Please contact us without hesitation for further information.