UL Smoke Detector, En54 Smoke Detector, Smoke Detector manufacturer / supplier in China, offering UL/En54 Approved Conventional Smoke Detector (SD119-2L), White Short Roller Ball Contact with Terminals, Roller Shutter Door Magnetic Contact Reed Switch and so on.
Min. Order / Reference FOB Price | |
---|---|
10 Pieces | Contact Supplier |
Local Area: | Ningbo, Zhejiang, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment |
Type: | Smoke Detector |
---|---|
Usage: | Fire Alarm |
Installation Mode: | Ceiling Mounted |
Specification:
Smoke Sensitivity:0.98~4%/FT Obsuration(UL standard)Ceiling Spacing:50 foot rating for heat sensor (55 degree)Reset Voltage:less than 1 voltReset Time:less than 1 secondAlarm Indicator:LED continuously emitting red lightRemote Output:25 mA max., diode gateTemperature Range:-10°C to 55°C,UL268 temperature 0~37.8 °CPermissible Current:80mA maximumHumidity:0 to 95% RH, no condensation or icingAlarm Contact:(for 4-wire)NO or NC Operation, Form A: 1.0A@30VDC/0.5A@125VACDimensions:100mm (dia) x 46mm (ht) with baseWeight:130g/set with base
Conventional Photoelectric Smoke Detector for Fire Alarm Control Panel Usage (SD119)
Product Features:
*2 or 4 wireOrder Information:
The range includes:
SD119-2:2 wire photoelectric smoke alarm
SD119-2-LED: 2 wire photoelectric smoke alarm with remote LED output
SD119-2H: 2 wire photoelectric smoke and heat alarm
SD119-2H-LED: 2 wire photoelectric smoke and heat alarm with remote LED output
SD119-4:4 wire photoelectric smoke alarm(12/24/48VDC)
SD119-4B: 4 wire photoelectric smoke alarm with Buzzer(12/24/48VDC)
SD119-4AR: 4 wire photoelectric smoke alarm with auto-reset function(12/24/48VDC)
SD119-4ARB: 4 wire photoelectric smoke alarm with auto-reset function and Buzzer(12/24/48VDC)
SD119-4H: 4 wire photoelectric smoke and heat alarm (12/24/48VDC)
SD119-4HB: 4 wire photoelectric smoke and heat alarm with Buzzer(12/24/48VDC)
SD119-4HAR: 4 wire photoelectric smoke and heat alarm with auto-reset function(12/24/48VDC)
Model
2/4
Wire
Voltage DC(Min./MAX.)
Standby Current(Max.)
Alarm Current(12/24V)
Surge Current(Max.)
Start-Up Time(Max.)
Permissible Current(Max.)
Cycle TimeAlarm ContactCertifiedSD119-22 10.8-33V80µA22/55mA160µA30Sec.80mA1-3Sec.-UL/ENSD119-2L2 10.8-33V80µA22/55mA160µA30Sec.80mA1-3Sec.Remote LEDUL/ENSD119-2H2135±5°F10.8-33V80µA22/55mA160µA30Sec.80mA1-3Sec.-UL/ENSD119-2HL2135±5°F10.8-33V80µA22/55mA160µA30Sec.80mA1-3Sec.Remote LEDUL/ENSD119-4-12/244 12/24V80µA30/45mA-30Sec.-1-3Sec.Form AUL/ENSD119-4H-12/244135±5°F12/24V80µA30/45mA-30Sec.-1-3Sec.Form AUL/ENSD119-4AR-12/244 12/24V100µA30/45mA-30Sec.-1-3Sec.Form A
Auto Reset
CESD119-4ARB-12/244 12/24V100µA30/45mA-30Sec.-1-3Sec.Form A
Auto Reset
CESD119-4B-12/244 12/24V80µA30/45mA-30Sec.-1-3Sec.Form ACESD119-4HB-12/244135±5°F12/24V80µA30/45mA-30Sec.-1-3Sec.Form ACESD119-4HARB-12/244135±5°F12/24V100µA30/45mA-30Sec.-1-3Sec.Form A