2 Wired 24V Conventional Fire Alarm Control Panel1. Strictly in accordance with the EN54 part 2&4 standard.
2. Modularized design with extendable zones from 1 to 32 zones.
3. With two-level control modes by lock
4. 24VDC & 5VDC power supply outputs.
5. FIRE & FAULT signal outputs.
6. Owns 2 general sounders outputs.
7. Each zone has 1 circuit detectors input .
8. Each zone can be disable by a button.
9. RESET button available
10.SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12.Low-battery level protection function, i.e., battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
13.GSM module for fire alarm by SMS is optional.
14 EIndustrial Adhesive Products conomic, user-friendly & convenient maintenance.
As the pics shows:
ITEM1Zonepanel2Zonepanel4-8Zonepanel12-32ZonepanelModelNo.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32Powerspecification
Mainssupplyvoltage110VACor240VACInternalpowersupply27.2VDCTotaloutputcurrentlimited500mA@240VAC500mA@240VAC3A@240VAC3A@240VACMainsupplymonitorforfaultYesBatteryprotectionforlowvoltageYesBatteries(defaultconfiguration)12V2AH*2Detectorcircuitspecification
Numberofcircuit124-164-32LinefaultmonitorforopencircuitYesLinefaultmonitorforshortcircuitYesLinefaultmonitorfordetectorremovalYes,ifEndofLineMonitorUnitfittedinplaceofEndofLineResistorEndofLinedevicGuide Rail e6.8kΩ,5%tolerance,0.25W(colourcode-blue,grey,red,gold)DetectorcontinuitydiodesSilicon1N4001orSchottkytype(requiredifEndofLineMonitorUnitfittedtogiveDetectorRemovalFault)Callpointresistorvalue470to680Ω,0.225or0.5wattMaximumnumberofsmoke/heatdetectorsperzone20(basedonatotaldetectorcurrentof2mA,eachdetectorconsuming100μA).Note:ifEndofLineMonitorUnitisfitted,forcorrectoperationmaxmumvoltagedropmustnotexceed12volts.MaximumnumberofmanualcallpointsperzoneNolimitSoundercircuitspecification
NumberofgeneralcircuiBoiler & Furnace ts2Endoflineresistorvalue6.8kΩ,5%tolerancIndustrial Equipment & Components e,0.25Oscillator W(colourcode-blue,grey,red,gold)LinefaultmonitorforopencircuitYesLinefaultmonitorforshortcircuitYesOutputsfusedAT400mAMaximumnumberofbells@20mAofeachsounderoutput20Fuses
Batteryfuse1.5AF20mmSounderoutputs500mAF20mmFireandfaultoutput
OutputtypeNCandNOrelayMaximumcurrent100mAConnectionblock
Largestacceptableconductorsize2.5mm2Smallestacceptableconductorsize0.75mm2Sizeandweight
Dimensions(mm)272*200*70mm320*231*90mm395X502X124362X565X124Weight(withoutbatteries)4kg5kg7kg8kgWeight(withbatteries)5.8kg6.8kg9.6kg12.5kg
Company InformationAsenware,manufacturer of fire alarm and fire suppression system since 2005.
Our headquarter is in London, UK, with factory Shenzhen, China.We keep our best service for our customers, and have a rich experienced engineer team to design and install
for overseas project.Product rangeAddressable fire alarm system
Conventional fire alarm system (2166 series)
FM200 gas suppression system (2159 series)
Fire pump
Fire hose/ hose reel and cabinet
ABC powder/ CO2 fire extinguisher
Emergency light system
Certificates
Contact