Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Extinguishant Control System, Extinguish Fire System, Extinguish Control Panel manufacturer / supplier in China, offering Fire Fighting Fire Alarm System with Fire Extinguishant Control Panel, AC220V Combustible Gas Detector Gas Alarm for Home Kitchen Using, Standalone Town Gas Detector LPG Leakage Gas Alarm Coal Gas Leakage Detector and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Detector Fire Alarm & Smoke Detector China Fire Protection Panel Security Alarm System Smoke Alarm Panel

China Fire Protection Panel Security Alarm System Smoke Alarm Panel

Get Latest Price
Min. Order / Reference FOB Price
1 6 (1.5A su US $120.00/ 6 (1.5A su
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Fire Alarm Host
Function: Networked
Usage: Fire, Smoke
ConTROL PANEL
The fire panel must be sited internally, in an area
where it is readily accessible by staff on duty and the
fire brigade. The Construction Equipment & Tools area should be clean and dry and
you should take into account any likelihood of
tampering or vandalism. The ambient light and
sound levels should allow the status of the indicators
to be clearly seen and the internal sounder to be
heard. Full details can be found in BS 5839: Pt1: 1988:
Section 15.3 "Fire Detection and Alarm Systems for
Buildings".

External (key-switch operated):

Reset/resound/test zone lamps evacuateSilence alarm soundersSilence fault sounders

Internal:

One man detector testZone isolateRevert to short-circuit: fire (no resistors in call points)

External indicators:

Sounder faultBattery/power supply faultMains onZone fireZone fault

Internal indicators:

Open circuit zone faultShort circuit zone faultZone isolatedEngineer test selected

Outputs:

Two sounder circuits (alarm relay contacts can be obtained by connecting a relay to a sounder circuit)

Ancillary connections for expansion modules will allow the following:

Repeater panelsMultiple sounder outputsConnection to landlord panel
2 (0.8A supply)4 / 6 (1.5A supply)8/10/12/14/16/18
(4.0A supply)Power specificationsMains supply voltage230±10%V AC, 50/60Hz230LCD Module ±10%V AC, 50/60Hz230±10%V AC
50/60HzInternal power supply27V DC27V DC27V DCTotal output current limited to800mA at 240V AC1500mA at 240V AC4000mA at 240V ACAuxiliary power output27V DC27V DC27V DCMains supply monitored for failureYesYesYesBattery charger monitored for failureYesYesYesBatteries monitored for disconnection and failureYesYesYesDetector circuit specificationNumber of circuits24 or 68, 10, 12, 14,16,or 18Line fault monitored for open circuitYesYesYesLine fault monitored for short circuitYes (can be disabled)Yes (can be disabled)Yes (can be disabled)Line fault monitored for detector removalYes, if end of line monitor unit fitted in place of end of line resistorEnd of line resistor (supplied) value6.8K Ohm, 5% tolerance, 0.25W6.8K Ohm, 5% tolerance, 0.25W6.8K Ohm, 5% tolerance, 0.25WDetector continuity diodesSilicone 1N4001 or Schottky type (required if end of line mLED Display onitor unit fitted to give detector removal fault)Call point resistor value (not supplied)470 to 680 Ohm, 0.5W470 to 680Ohm, 0.5W470 to 680Ohm, 0.5WMaximum number of smoke Riveter detectors per zone20 (maximum detector current = 2mA) 20 (maximum detector current = 2mA) 20 (maximum detector current = 2mA) Maximum number of manual call points per zoneNo limitNo limitNo limitSounder circuit specifications:Number of circuits222End of line resistor value6.8K Ohm, 5% tolerance, 0.25W6.8K Ohm, 5% tolerance, 0.25W6.8K Ohm, 5% tolerance, 0.25WLine fault monitored for open circuitYesYesYesLine fault monitored for short circuitYesYesYesOutputs fused at1A1A1.6AMaximum total output current all outputs800mA1500mA4000mAHand Tools Maximum no of bells at 25mA each bell3256120Maximum no of electronic sounders at 20mA4070150Auxiliary relay contacts (do not connect mains voltages)1A 30V DC max
voltage free1A 31V DC max
voltage free1A 32V DC max
voltage freeFuses-all fuses compliant to ice (EN60127 PT2)Mains terminal block200mA/T 20mm400mA/T 20mm630mA/T 20mmSounder outputs1A/F 20mm1A/F 20mm1.6A/F 20mmAuxiliary output1A/F 20mm1A/F 20mm1A/F 20mmBattery fuse1.6A/F 20mm1.6A/F 20mm3A/F 20mmDoor retaining magnetsdo not use panel power supply as you will drastically reduce battery standby timeConnection blockLargest acceptable2.5mm22.5mm22.5mm2Smallest acceptable conductor size0.75mm20.75mm20.75mm2DimensionsEnclosure (width x height x depth)415 x 265 x 100mm415 x 265 x 100mm415 x 265 x 100mmWeight (without batteries)5100g5200g5500