FLOR ConTROL TOOLS
XO/XD CIRCULATING SLEEVEThe "XO/XD" Circulating Sleeve provides a convenient way to establish or shut off communication between the tubing and the annulus. Any number of these sleeves may be run in a tubing string, and any or all of them may be opened or closed in one run by standard wireline methods.
Design Features:Features a nipple profile above and a packing bore above and below the communication ports.Ports can be closed without leaving any obstructions in the tubing once the shifting operation is completed.The Model "B" Shifting Tool is used to open (jarring down) or close (jarring up) the "XO/ XD" Circulating sleeve.
XO CIRCULATING SLEEVEPart NumberSizeODSeal BorePressurePort AreaThreadin.in.in.psi.in2D90-7187-2012.3753.0631.8757,0001.8042 3/8" EUED90-7231-2012.8753.6682.3137,0002.4052 7/8" EUED90-7275-2013.5004.2752.7507,0004.45431/2" EUED90-7281-2014.2902.8137,0004.454
XD CIRCULATING SLEEVEPart NumberSizeODSeal BorePressurePort AreaThreadin.in.in.psi.in2D90-7187-3012.3753.0631.8757,0002.7612 3/8" EUED90-7231-3012.8753.6682.3137,0004.2012 7/8" EUED90-7275-3013.5004.2752.7507,0005.9393 1/2" EUED90-7281-3014.2902.8137,0006.210
XA CIRCULATING SLEEVEThe "XA" Circulating Sleeve provides a convenient way to establish or shut off communication between the tubing and the annulus. Any number of these sleeves may be run in a tubing string, and any or all of them may be opened or closed in one run by standard wireline methods.
Design Features:Features a nipple profile above and a packing bore above and below the communication ports.Ports can be closed without leaving any obstructions in the tubing once the shifting operation is completed.The Model "B" Shifting Tool is used to open (jarring up) or close (jarring down) the ' XA" Circulating sleeve.
SPECIFICATIONSPart NumberSizeODSeal BorePressurePort AreaThreadin.in.in.psi.in2D90-7187-4012.3753.0631.8757,0001.80423/8" EUED90-7231-4012.8753.6682.3137,0002.40527/8" EUED90-7275-4013.5004.2752.7507,0004.4543 1/2" EUED90-7281-4014.2902.8137,0004.454
T-2 ON-OFF TOOLThe T-2 On-Off Tool is a tubing disconnect device that has an internal blanking plug locking profile with seal bore for utilizing flow control equipment. The Overshot has a box looking up which connects to tubing string and a pin looking down off the Stinger which connects to the packer. The T-2 On-Off Tool has two basic components that comprise the Overshot. The Top Sub which contains two bonded rubber steel seals and the Jay Latch which has a J Slot configuration to locate and latch the On-Off Tool Stinger. The Jay Latch also has a wash over shoe configuration which allows cutting through debris. The Overshot automatically Jays up on the Stinger when lowered into well.
Applications:Item is designed to isolate a lower zone or to disconnect the tubing without releasing or disturbing the packer.Standard left hand releaseAutomatic jay upBonded sealsAll nipple profiles available for stingerFull open or solid stinger available10K ratedWash over shoe on all models
Part Number (without shear pin)Part Number (with shear pin)CasingODOD Of StingerTensionPressureThreadin.in.in.lbs.psi.in.D90-5237-604D90-5237-5044.53.7502.60965,00010,0002 3/8" EUED90-5237-605D90-5237-5055.54.5002.6092 3/8" EUED90-5287-605D90-5287-5055.54.5003.25075,0002 7/8" EUED90-5287-607D90-5287-50775.8753.2502 7/8" EUE
PX PLUGPX Plug
The PX Plug is a device capable of holding pressure differentials from above or below when set at any X Profile Nipple of the same size.
The PXN Plug is a device capable of holding pressure differentials from above or below when set at any XN profile Nipple of the same size.
SPECIFICATIONS
Part NumberTubing SizeSeal ODNoGo ODPressurein.in.in.psi.D91-6187-2002.3751.8751.86510,000D91-6231-2002.8752.3132.302D91-6275-2003.5002.7502.740D91-6281-2002.8132.802
PXN PLUGSPECIFICATIONSPart NumberTubing SizeSeal ODNoGo ODPressurein.in.in.psi.D91-6187-2012.3751.8751.86510,000D91-6231-2012.8752.3132.302D91-6275-2013.5002.7502.740D91-6281-2012.8132.802
X & XN LOCK MANDREL PX/PXN EQUALIZING PRONG AND VALVEX LOCK MANDREL
The "X" Lock Mandrel is a selective set lock designed to be landed and locked, downhole, in a "X ' Profile Nipple. Equalizing Sub Assemblies and a variety of sub-surface flow control devices may be attached to this lock mandrel before running.
XN Lock Mandrel
The "XN" Lock Mandrels are similar to the "X" except for the locking keys. The keys for the "XN" Mandrels are chamfered so they will pass through a "X" Profile Nipple uphole. This allows the "XN" Mandrel and flow control to be lowered through "X" Profile Nipples in the tubing string to land in a "XN" Profile Nipple which is always installed in the lower end or on bottom of the tubing string. The NoGo shoulder of the "XN" Lock Mandrel is located on the flow control device.
X/XN LOCK MANDRELXN Model Part NumberSizeIDX Model Part Numberin.in.D91-6187-2031.8751.38D91-6187-202D91-6231-2032.3131.81D91-6231-202D91-6275-2032.7502.31D91-6275-202D91-6281-2032.8132.31D91-6281-202
PX / PXN Equalizing Prong and Valve
The PX/PXN Equalizing Prong and Valve assembly, when attached to an X or XN Lock Mandrel Assembly, converts the lock mandrel to a plug, with equalizing device, capable of holding pressure differentials from above or below.
differentials from above or below.
PX/PXN EQUALIZING PRONG AND VALVEPX Model Part NumberSizeTop ODin.in.D91-6187-2041.8751.375D91-6231-2042.3131.375D91-6275-2042.7501.375D91-6281-2042.8131.375
FWG BY-PASS BLANDING PLUGThis Plug allows fluid to by-pass through the side ports, when running in the well. once Plug is locked in a "F" type profile, pressure can be held in either direction. After well has been repaired or tested, Plug can be equalized and pulled with standard wireline tools.
To Run: C-1 Running Tool
To Pull: SB or JDC Pulling Tool, with B Probe
SPECIFICATIONSPart NumberTubing SizeSeal ODNoGo ODPressurein.in.in.psi.D91-6178-4002.3751.7811.80210,000D91-6181-4001.8121.865D91-6187-4001.8751.905D91-6225-4002.8752.2502.302D91-6231-4002.3132.365D91-6275-4003.5002.7502.802D91-6281-4002.8132.865
RZG BY-PASS BLANKING PLUGThis Plug allows fluid to by-pass through the side ports, when running in the well. once Plug is locked in a "R" type profile, pressure can be held in either direction. After well has been repaired or tested, Plug can be equalized and pulled with standard wireline tools.
To Run: C-1 Running Tool
To Pull: SB or JDC Pulling Tool, with B Probe
SPECIFICATIONSPart NumberTubing SizeSeal ODNoGo ODPressurein.in.in.psi.D91-6178-4012.3751.7811.77610,000D91-6181-4011.8121.807D91-6187-4011.8751.870D91-6225-4012.8752.2502.245D91-6231-4012.3132.307D91-6275-4013.5002.7502.745D91-6281-4012.8132.802
FWB DOWN INSTRUMENT HANGERThis Instrument Hanger is used to land and lock geophysical instruments in "F" type profiles to allow recording of reservoir data.
Features/Benefits:It allows the well's Safety System to remain in full operation during the survey.It allows removal of wireline from a corrosive environment to prevent damage of wireline.Several wells may be surveyed with one wirelineTo Run: "C-1" Running Tool
To Pull: SB or JDC Pulling Tool, with B Probe
SPECIFICATIONSPart NumberTubing SizeSizeNoGo ODBottom Threadin.in.D91-6178-4022-3/8"1.781.8023/4"-16UNFD91-6181-4021.811.865D91-6187-4021.871.905D91-6225-4022-7/8"2.252.302D91-6231-4022.312.365D91-6275-4023-1/2"2.752.802D91-6281-4022.812.865
RZB DOWN INSTRUMENT HANGERThis Instrument Hanger is used to land and lock geophysical instruments in "R" type profiles to allow recording of reservoir data, unit.
Features/Benefits:It allows the well's Safety System to remain in full operation during the survey.It allows removal of wireline from a corrosive environment to prevent damage of wireline.Several wells may be surveyed with one wirelineTo Run: "C-1" Running Tool
To Pull: SB or JDC Pulling Tool, with B Probe
SPECIFICATIONSPart NumberTubing SizeSizeNoGo ODBottom Threadin.in.D91-6178-4032-3/8"1.781.7713/4"-16UNFD91-6181-4031.811.802D91-6187-4031.871.865D91-6225-4032-7/8"2.252.240D91-6231-4032.312.302D91-6275-4033-1/2"2.752.740D91-6281-4032.812.802
FB-2 EQUALIZING CHECK VALVEEqualizing Check Valves are sometimes called "Standing Valves" because they prevent fluid flow in one direction (downward) while allowing full fluid flow in the opposite direction (upward). The "FB-2" seats on the top NoGo shoulder of a "F" type profile which prevents downward movement. It is not locked into the profile, and has a built-in method of allowing equalizing before pulling.
To run: C-2 running tool
To pull: SB pulling tool
SPECIFICATIONSPart NumberTubing SizeSeal ODODPressurein.in.in.psi.D91-7178-1002.3751.7811.8025000D91-7181-1001.8121.865D91-7187-1001.8751.905D91-7225-1002.8752.2502.302D91-7231-1002.3122.365D91-7275-1003.5002.7502.802D91-7281-1002.8132.865
RB-2 EQUALIZING CHECK VALVEEqualizing Check Valves are sometimes called "Standing Valves" because they prevent fluid flow in one direction (downward) while allowing full fluid flow in the opposite direction (upward). The 'RB-2" seats on the bottom NoGo shoulder of a "R" type profile which prevents downward movement. It is not locked into the profile, and has a built-in method of allowing equalizing before pulling.
To Run: C-1 Running Tool
To Pull: SB Pulling Tool
SPECIFICATIONSPart NumberTubing SizeSeal ODODPressurein.in.in.psi.D91-7178-1012.3751.7811.7715000D91-7181-1011.8121.802D91-7187-1011.8751.865D91-7225-1012.8752.2502.240D91-7231-1012.3122.302D91-7275-1013.5002.7502.740D91-7281-1012.8132.802