Application Scope:
EASTBIO® GBCL Series in-situ sterilizable magnetic stirred glass fermenters are ideal appliances for precise fermentation experiment in microbiological laboratory for both universities, research centers, institutes as well as private enterprises. It is normally applied for culture medium selection, fermentation process optimization and verification of strains as well as its production process.
Technical Data of GBCL Type Glass FermenterItem | Description | ModelGBCL-5/GBCL-7/GBCL-10Total Volume5L/7L/10LWorking Volume3L/5L/7LMaterialBorosilicate glass vessel with stainless steel 316L top end and bottom endAerationGlass rotameter and ring sparger, sterilizable 0.2um Air filterAgitationSpeed adjustable: 200-800rpm±1%AgitatorTwo 6-blade Rushton impellers supply as defaultDriveMagnetic stirred from bottom without mechanical sealMotorDC motor with digital driverTemperaturePt-100 probe, automatic controlpHMettler Toledo / Hamilton electrode, pH2.0-12.0±0.1DOMettler Toledo / Hamilton electrode, 0-100% or 0-200%AntifoamSterilizable conductivity probe, automatic controlPeristaltic poump4 peristaltic pumps each function for acid, alkali, antifoam and feedingStructureFloor standSterilizationIn-situ sterilized with clean steam (provided with stainless steel safety cover)ControlEBio™ Data Aquisition and Automatic Control System mainly based on SIEMENS PLC, displayed and operated on colorful touch screen monitorOptional1. MFC for areation
2. Multi-feeding
3. Oxygen enrichment
4. Exhaust O2/CO2 analysis
5. Weighing
6. Special agitatorTechnical Specifications:
Model: GBJL-5, GBJL-8, GBJL-10
Total Volume: 5L, 8L, 10L
Loading Quotiety: 65-80% (70% is optimum)
Material: Special glass vessel with stainless steel top and bottom end
Agitation: Flat-blade/oblique blade/curved blade/axial flow impeller for choice
Type of Drive: Magnetic stirred from bottom
Sealing Form: Magnetic coupling without mechanical seal
Structure: Floor stand
Sterilization: In-situ sterilization
Control Method: EbioTM Data Aquisition and Automatic Control System mainly based on Siemens PLC, displayed and operated on colorful touch screen monitor.? Details of Ebio control system
Suitable for anaerobic culture too
Characteristics:
The in-situ sterilization process is similar to the process of scale-up experiments. The sterilizing operation is safe and reliable, and the culture medium concentration is accurate after sterilization. It applies magnetic coupling to eliminate mechanical seal leakage risk. The fermenter can be observed clearly, dismounted and mounted easily, and operated conveniently.