Ethernet, Outdoor, 4G manufacturer / supplier in China, offering Ethernet 4G Lorawan Outdoor Gateway for Remote Street Light Management, Lora 5pin NEMA Receptacle for Street Light Dimming, Lora 7pin NEMA Receptacle for Street Light Dimming and so on.
Min. Order / Reference FOB Price | |
---|---|
5 Piece | US $180.00/ Piece |
Local Area: | Dongguan, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | T/T |
Breaking Capacity: | Low Voltage Circuit Breakers |
---|---|
Operation: | Remote Control & Manual Control |
Speed: | High-Speed Circuit Breaker |
Brief introduction:
Features:
Protection function: Monitor the power consumption of the output terminal and automatically cut off the power supply if an abnormal situation occurs.Automatic coincidence: Realize automatic reclosing in unattended environment after the line returns to normal.Metering function: With high-precision voltage and current real-time monitoring and energy metering, which will help to analyze energy consumption of the electricity devices.Wireless communication: With local RS485 communication and GPRS (2G / 3G) wireless communication, it can realize remote opening and closing control, fault inquiry and timing reporting of measurement data.Devices management: With perfect fault condition monitoring (overload, short circuit, over voltage and under voltage, phase loss, phase imbalance) and can report and give alarm prompts in real time.Electricity management: With a rate measurement in accordance with the national standard and can realize freezing data operation. Combined with wireless communication, remote management of electricity charges can be realized, and if arrears, the loop will close and all the devices will stop working.Humanized display interface: With an oversized LCD screen for remote and local information communication. The metering parameter and device status information is clear at a glance.Technical parameters:
Communication Mode Standard RS485 / NetworkGPRS-2G/3G+RS485Power
DataUn(V)230V~/400V~ 3x230V~/3x400V~Ib(A)20A 20A Imax(A)63A80AHz50/60HzProduct StandardGB10963.1,GB/T17215.211-2006, GB/T17215.322-2008,
DL/T1487-2015, DL/T1485-2015, DL/T533-2007,AccuracyActive
PowerChass 1.0Reactive
PowerChass 1.0Protectionshort circuit, overload, over/under voltage, phase loss, alarm, remote
control, etcPower consumption0.5WConstant400 imp/kWhPower lines 1 LineLimit breaking
capacity
6000AInsulated voltage
withstand
2500V/min Tripping time:<0.2SInstantons tripping
curve
TypeB, TypeC, TypeDSurge Protection6000VOutput auxiliary
contact
5A max(250VAC)resistor loadOver/under voltage
value
280/115V( default value, configurable in platform)Overload current
limit
63/80A (default value, configurable in platform)Electric life≥5000timesMechanical life≥10000timesOperation timeTrip≤0.3s, Reclose≤0.8s(exclude time delay)ConnectionDirect ConnectionInstallationDIN installation of 35mmProtection gradeIP20Work/storage
temperature
-25°C~+65°C / -40°C~+75°CRelative humidity≤95%
Unlock releaseIdentified the circuit fault, the electrician should pull out the safety lock and hang with a lock to solve the problem. Then, push back the safety lock, and try manually switching on the handle. If unsuccessful, electrician needs to check credit overdue or remotely switched off, by either RS485 or GPRS.
Safety lockIt is under operation mode while safety lock not pulled out.It is under maintenance mode while safety lock is pulled out and needs to hang a lock. This safety lock has interlock with handle, and can't switch on, even manually, while lock pulled out. More security to maintenance electrician.