Guangzhou Happycare Electronics Co.,LTD is a professional medical manufacturer with rich experience in providing one stop service,we manufacture B ultrasound,Homecare products,Laboratory Machine,Veter...
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $895.00/ Piece |
Local Area: | Guangzhou, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, Paypal, Western Union |
Charge Time: | 8 Sec. to 150j; 10 Sec. to 200j (New Battery) |
---|---|
Energy Sequence: | 150, 150, 200j |
Trademark: | Happycare |
Features for HC-C017 Hot sale Automated AED Automated External Defibrillator:
HC-C017 AED Defibrillator (Automatic External Defibrillator) is a defibrillation device, which is safe, portable and easy to use. It can be applied in family and public place to give first aid for the sudden death symptom. Combined with advanced ECG analytical technique, the defibrillator can analyze the patients ECG, make a judgement for the patients cardiac condition and indicate whether the defibrillation is needed and the defibrillation strength. It can not only enhances the success rate of defibrillation, but also reduce the injury of defibrillation to heart to the utmost extent.There is low requirement for the operator to use the device. The defibrillator will guide the operator to carry out defibrillation treatment via voice prompt step by step, give safety alert if the occasion arises. It can carry out early defibrillation treatment effectively and protect the operator farthest, being very applicable to the emergency treatment for the sudden cardiac death patient in family and public place.
Three-step defibrillation process
Two-button operation
Extensive voice and visual prompts for the operator
Biphasic energy output
Lock-out protection to prevent inadvertent defibrillation
PC-based event review (optional)
Multilingual selections are available. (optional)
Output
Biphasic Truncated Exponential
Energy Sequence
150, 150, 200J
Charge Time
8 sec. to 150J; 10 sec. to 200J (New Battery)
Analysis Time
9 sec.
The maximum time from the initiation of rhythm analysis to
readiness for discharge with a new battery
Less than 30 seconds
The maximum time from the initiation of rhythm analysis to
readiness for discharge after 6 shocks
Less than 35 seconds
The maximum time from initially switching power on to
readiness for discharge
Less than 25 seconds
Audible prompts
22 audible prompts
Visual prompts
LED prompts
Controls
Two buttons-ON/Off, Shock
Output Energy Accuracy
±15% into any impedance from 25 to 175Ω
The Maximum Voltage
1200±50V
Output disabled when the patient impedance is outside limits
20Ωto 200Ω
Physical
Dimensions
303*216*89mm
Weight
2.0kg
Operating Temperature
0°C to 40°C
Operating Humidity
Relative humidity between 30% and 95% (non-condensing)
Storage Temperature (without battery)
-20°C to 55°C
Storage Humidity (without battery)
Up to 95% (non-condensing)
Battery
Part No.
CR123A-4*2
Non-rechargeable
12V DC, 2.8Ah
Capacity
At 150 Joules
Pictures for HC-C017 Hot sale Automated AED Automated External Defibrillator: