Solar Inverter, MPPT Solar Controller Inverter, 1kw to 3kw 12V/24V Inverter manufacturer / supplier in China, offering Must PWM High Efficiency 5kVA DC 48V to AC 220V Pure Sine Wave Solar Inverter, 1kw to 12kw off-Grid Home Power System with Pure Sine Wave Inverter, Must Smart Battery Charger 4kVA/3.2k Watt Parallel Solar Hybrid Inverter and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | Contact Supplier |
Local Area: | Shenzhen, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, WesternUnion, Small-amountpayment |
Phase: | Single Phase |
---|---|
Type: | On-line |
Protection: | Most of Power Problems |
High efficiency low noise online ups
ModelH1K(S)H1.5K(S)H2K(S)H3K(S)CAPACITY1000 VA/700 W1500 VA/1050 W2000 VA/1400 W3000 VA/2100 WINPUTVoltage RangeLow Line Transfer160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or80 VAC / 70 VAC / 60 VAC / 50 VAC ± 5 %(based on load percentage 100% - 80% / 80% - 70% / 70% - 60%/60% -0)LowLine Comeback175 VAC ± 5 % or 85 VAC ± 5 %High Line Transfer300 VAC ± 5 % or 150 VAC ± 5 %
High Line
Comeback290 VAC ± 5 VAC or 143 VAC ± 3 VACFrequency Range40 Hz ~ 70 HzPhaseSingle phase with groundPower Factor≥ 0.99 @ 220-230 VAC (input voltage)OUTPUTAC Voltage Regulation (Bat. Mode)±3%Frequency Range
(Synchronized Range)47 ~ 53 Hz or 57 Hz ~ 63 HzFrequency Range (Bat. Mode)50 Hz ± 0.25 Hz or 60 Hz ± 0.3 HzCurrent Crest Ratio3:1Harmonic Distortion<= 3 % THD (Linear Load)<= 4 % THD (Linear Load)<= 6 % THD(Non-linear Load)<= 7 % THD(Non-linear Load)Transfer TimeAC to DCZeroInverter to Bypass4 ms (Typical)Waveform (Bat. Mode)Pure Sine WaveEFFICIENCYTo AC Mode85%88%To Battery Mode83%BATTERYStandard ModelBattery Type12 V / 7 AH12 V / 9 AH12 V / 7 AH12 V / 7 AHNumbers3388Typical Recharge Time4 hours recover to 90% capacityCharging Current (max.)1.0 ACharging Voltage41.0 VDC ± 1%102.1 VDC ± 1%Long-run ModelBattery Type/NumbersDepending on the capacity of external batteriesCharging Current (max.)8.0 ACharging Voltage41.0 VDC ± 1%102.1 VDC ± 1%INDICATORSLCD PanelUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditionsALARMBattery ModeSounding every 4 secondsLow BatterySounding every secondOverloadSounding twice every secondFaultContinuously soundingPHYSICALStandard ModelDimension DXWXH (mm)390 X145 X 210455 X 190 X 330Net Weight (KGS)13142628Long-run ModelDimension,DXWXH (mm)397 X 145 X 220421 X 190 X 318Net Weight (KGS)713OPERATING ENVIRONMENTHumidity20-90 % RH @ 0- 40°C (non-condensing)Noise LevelLess than 45dB @ 1 MeterMANAGEMENTSmart RS-232/USBSupports Windows®98/2000/2003/XP/Vista/2008,Windows®7,Linux,and MACOptional SNMPPower management from SNMP manager and web browser