High Frequency 150KV double column X-ray System MSLHX19 with Flat panel detector
Product descriptions
MSLHX19 digital X-ray system is a self-developed electric double-column DR. It combines the actual clinical needs of hospitals to launch a digital medical imaging product with high-level design concept, professional manufacturing process and strict testing process.
Flexible and reliable rack design
Reliable rack profile with in-line rails
One-piece design, flexible operation
Power assisted, easy to operate with one hand
Rugged design for consumable parts
Ensure equipment mechanical life
A variety of model specifications, single detector, dual detector configuration can be arbitrarily matched to meet a variety of clinical needs of customers
High performance high voltage generator
500KHZ UHF inverter frequency, KV rise time <500 microseconds, ripple factor <1%, clearer image, network voltage fluctuation +30%, the machine can work stably
Optional AEC function to ensure uniform and stable pictures for all parts of the film, greatly simplifying the doctor's operation process
High efficiency tube
Double focus, 0.6/1.2 MM, full presentation of tssue details, clear image, accurate diagnosis
High heat capacity tube assembly heat capacity, even more patients, do not have to worry about the tube overheating strike
Power requirementsVoltageAC380V/400V±10%Frequency50HzResistance≤0.1ΩCapacity≥63kVAMechanical parameterColumn vertical movement distance1160mm (Error: ±5%)Column lateral movement distance1730mm (Error: ±5%)Chest film frame lifting distance≥1200mmTube assembly rotation angle-90°~+90°, manual rotationColumn rotation angle-180°~+180°, manual rotationPatient table X-axis movement distance900mm (Error: ±5%)Patient table Y-axis movement distance260mm (Error: ±5%)Patient table dimensions (LxWxH)2110mmx822mmx656mm (Error: ±5%)Max. Patient Weight (kg)150kgEffective filtration of photographic table0.2 mmAlHigh voltage generatorInput power voltageAC 380V/400V±10%Frequency50HzOutput nominal electric power50kW (500mA,100kV,0.1s)Tube voltage/kV40kV~150kV, digital button adjustment, minimum adjustment step length is 1kV;Tube current/mA10mA~630mA, meet the value of R'10 number system in ISO 497, adjusted in a multilevel manner by digital button;Loading time1ms~6300ms, meet the value of R'10 number system in ISO 497, adjusted in a multilevel manner by digital button; AEC nominal
shortest irradiation time: 1.6msCurrent time product/mAs0.1mAs~630mAs, meet the value of R'10 number system in ISO 497, adjusted in a multilevel manner by digital button;Exposure technologykV-mA-ms, kV-mAsLoading conditions at Max. mA79kV,630mALoading conditions at Max. kV150kV,320mAX-ray tubeAnode input powerLarge focal spot: 50kW;
Intermediate focal spot: 20kWFocal spot0.6/1.2mmAnode speed2700RPM (r/min)Nominal tube voltage150kVAnode heat content163kJ (230kHU)Radiation spectrum characteristic of target materialSee appendix 10.4Heat capacity of X-ray tube assembly900kJ (1250kHU)Target angle12°Inherent filtration1.3mm Al/75kVEnvelope voltageSee appendix 10.4Envelope currentSee appendix 10.4Weight16kgBeam limiting deviceInherent filtration1.5 mm AlMax. tube voltage150kVMean exposure intensity>100Lux, SID100cmLight field switchManualExposure time30s±5sInput powerDC24V±2.4V,10VAMin. irradiation field<30mmx30mm at SID 100cmMax. irradiation field430mmx430mm at SID 100cmLight field deviation≤2%Anti-scatter GridGrid 1: Ratio 8:1; grid density: 230lp/cm; focal distance:130cmGrid 2: Ratio 10:1; grid density: 230lp/cm; focal distance:100cmDetector
CareView1500LDimensions35cmx43cmEffective number of bits≥14bitLimiting resolution≥3.4lp/mmDetector
CareView1800LDimensions43cmx43cmEffective number of bits≥14bitLimiting resolution≥3.6lp/mmImage workstationHard-disk capacity≥500GBMemory≥4GBProcessor≥3.2GHzWorking environmentRelative humidity30%~75%Atmospheric Pressure70kPa~106kPaTemperature10ºC~40ºCStorage and transport environmentRelative humidity10%~95%Atmospheric Pressure70kPa~106kPaTemperature-10ºC~50ºC