High Frequency online UPS LED Display 1K-20KVA
1: online UPS with LED Display for UPS Status
2: High Frequency UPS with N + X parallel redundancy
3: IGBT+DSP (TI) technology for High Frequency online UPS
4: Maintenance bypass switch for LED UPS 6k to 20K
High Frequency online UPS LED Display 1K-20KVA
KEY FEATURES
1: True on-line double conversion technology with advanced microprocessor control
2: Wide input voltage range
3: Zero transfer time
4: Protection against all type of power problems, Like: Power sags, high voltage spikes, switching transients, power surges, noise, frequency variation, brownout. Overload, Short Circuit, Overcurrent, Unbalanced Loads, Overvoltage
5: Self test while start of the UPS
6: Site wiring fault warning
7: On-battery power-on function
8: Smart RS232 and USB communication interface
9: Intelligent SNMP Card slot available
10: Built-in Sealed lead acid, maintenance free battery
11: Pure sine wave output
12: Single Phase In/Out for UPS 1-10KVA, Three Phase In and Single Phase out for UPS10-20KVA
13: LED Display for UPS status
14: Microprocessor control guarantees high reliability
15: Comprehensive self-protection design
16: Audible alarm mute
17: Cold start function
18: Auto self-testing system while turning on UPS
19: Maintenance bypass switch for 6k to 20K
20: N + X parallel redundancy and capacity expansion for 6k to 20K
21: MCU (Freescale) +IGBT+DSP (TI) technology and double conversion structure
online UPS MODELDX6KDX10KDX6KLDX10KLDX3110KLDX3115KLDX3120KLCAPACITYVA/W6KVA/4.8KW10KVA/8KW6KVA/4.8KW10KVA/8KW10KVA/8KW15KVA/12KW20KVA/16KWINPUTNominal Voltage 220/230/240VAC380VACVoltage Range120-275VAC210-475VACFrequency Range46-64Hz: 50Hz, 60Hz auto sensePhaseSingle phase with GroundThree phase (4 Wires+Ground) Power Factor>=0.99>=0.95OUTPUTVoltage 220/230/240*(1±1%)VACFrequency50/60Hz(Adjustable)
50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.1%)
60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.1%)Wave FormPure Sine WavePower Factor0.8Harmonic Distortion =<2% THD (Linear Load), =<6% THD (Non-Linear Load)Overload CapacityNormal when load < 105%; 105%-125% for 1 min, 125%-150% for 30secCurrent Crest Ratio3:1ConnectionsTerminal blockEfficiencyTo AC Mode88%85%To Battery Modeup to 90%BatteryTypeSealed free maintenance lead acid batteryNominal DC voltageBuilt in batteries 12v7.2ah*16pcs192VDC192VDCQuantity16pcs16pcsDepends on requested back-up timeDepends on requested back-up timeBack-up Time (Full load)>=7 minutes>=5 minutesDepends on the capacity of external battery bankDepends on the capacity of external battery bankRecharge Time7 hours to 90%Depends on the capacity of external battery bankDepends on the capacity of external battery bankCharge current(MAX)2.0A4.2A or 8A4.2A or 8ACharge voltage220Vdc ± 1%BypassAutomatic TransferOn overload and UPS failureBefore UPS Power-onDefault "NO" user adjustable to "YES"Transfer Time ZeroIndicatorsLED DisplayUPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault codeAudible Alarm Bypass, On battery mode, Battery low, Overload, FaultAcoustic noiseAt 1 meter distance<55dB<60dBCommunicationsIntelligent RS232 serial portWindows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MACSNMP (Optional)Power management from SNMP manager and web browserUSB (Optional)Windows family software and Mac OSEnvironmentalOperating Temperature0~40centi-degreeOperating Humidity20~90% ( Non Condensing)WeightNet weight (kg)5767.51820273535UPS DimensionL*W*H (mm)500*248*616500*248*616500*240*460500*240*460500*248*616500*248*616500*248*616There are two types: Standard type and Professional type, Professional type is with EPO, online maintenance and other functions.