Business Type:
Manufacturer/Factory
Business Range:
UPS, Solar Inverter
Establishment:
2012
R&D Capacity:
ODM, OEM
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion
Main Markets:
Southeast Asia, Middle East
OEM/ODM Service
Sample Available

MPPT Solar Charge Controller, Solar Charger, Solar Energy manufacturer / supplier in China, offering Auto Detection 48V 40A Solar Charger for PV System Solar Charger Controller 40A 60A, Online UPS Double Conversion 6kVA, 10kVA, 15kVA, 20kVA UPS, Sine Wave Power Inverter with AVR Function 1000W to 3000W and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Supply & Distribution UPS China High Frequency Three Phase Industry Online UPS

China High Frequency Three Phase Industry Online UPS

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $5000.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion
Phase: Three Phase
Type: On-line
Protection: Auto Self-Protection
Main Features:
1. Excellent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard the UPS's security of operation in bad environment.
2. N+X parallel redundancy (compatible to battery share in the parallel mode)
The maximum of the inbuilt parallel mode is 8 UPS without any other external accessories, which helps the customer to extend the system capacity with low cost. N stands for the minimum amount of UPS in the load and X stands for the amount of redundant UPS in the system. The bigger the number of X is, the higher the reliability of the system.
The advanced controlling strategy is adopted to save the customer's investment by sharing a battery unit in the parallel redundancy mode.
3. Intelligent management of battery charging and discharging
The CPU controlled advanced intelligent charging of battery enables the UPS's charger to rectify the charging parameter, and provide the optimum charging modes in the answer to the environment, types and amounts of cells, and the using condition of the battery. The scientific charging mode extends the battery's service lifetime. The optional addition to charging units shortens the time duration for the battery units recharging.
4. Frontal-board LCD display panel operation and maintenance
The full consideration of customer's efficiency in using the UPS is embodied in the module design and frontal-board maintenance, which saves time for repairing and improves the machine's usability.
5. Twin-channel line input
The UPS provides customer security in power supply with intelligent choice between two-line input or one-line input according to the actual condition.
6. Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot are provided and CMC, WebPower cards of ZLPOWER Company are available for the realization of remote management and monitoring. In addition, the optional AS400 card is suitable for the connection of stem point, which enriches the customer's choice out of the monitoring demand.
7. High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output and reliability.
8. Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help to reduce the power loss of UPS.
The EX33 series UPS is designed according to main power grid with a broader range of input voltage from 210VAC to 475VAC, which ensures that it can be applicable in the awful grid environment or different power supple equipment like generator with its extraordinary input frequency.
The factor that the technology of IGBT FM intelligent rectifier and inverter is used, the input power factor is as high as 0.99, and the input current harmonic wave is as low as 3% makes the output voltage electric property more extraordinary.
Powerful overload capacity: The UPS can work normally under the condition of 110-125% load to 10 minutes, and 1 minute in the condition of; 125-150% load. It also has the output short protection capability.
9. Flexible battery arrangement
Flexible arrangement of the amount of accumulators in each battery (32, 30, or 28) can be achieved through the parameter resetting in the EX33 series UPS, which effectively solves the question that the damage of some individual cell may influence the life of the whole battery unit by eliminating the damaged ones from the unit in the process of using UPS.

online UPS ModelEX3320KEX3330K EX3340K EX3360K EX3380K Rated Capacity20KVA/16KW30KVA/24KW40KVA/32KW60KVA/48KW80KVA/64KWInput Voltage210-475VACFrequency 40-70Hz Phase LineThree-phase 4 line + earth lineTHDI<3%Input Power Factor>0.99Twin-channel Line InputYes BatteryTypeValve-regulated lead-acid storage batteryStandby TimeDepended by external battery bank Output Voltage380VAC / 220 VACFrequency 50/60HzPhase lineThree-phase 4 line + earth lineRated output power factor0.8Overload Capacity125% maintain 10minutes150% maintain 1minutesEfficiency Line Input Mode93%94%BAT Mode 93%94%ECO Mode98%Intelligent Speed Control of Fan yesDisplay Device LCDI/O voltage, current, frequency, BAT voltage, charging current value, discharging current value, fault display, fault, warningLEDThe operation state of UPSWarning DevicesTwo ways of alerting: BUZZER sound, lamp signal, Communication InterfaceRS232, AS400, RS485, Service, EPO, BAT temperature compensation, Intelligent Slot Operation Temperature0-40centi-degreeEnvironment Humidity<95% (non condesing)Weight Net weight(include transformer)82Kg/208Kg110Kg/275Kg114Kg/314Kg282Kg306KgGross weight(include transformer)122Kg/248Kg160Kg/325Kg164Kg/364Kg356Kg380KgSize L*W*H(mm)643x420x925710x470x1150800x600x1850