Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Thermocouple Heads, Terminal Heads, Connection Heads manufacturer / supplier in China, offering Type K Aluminum Thermocouple Heads (KNE), Micc High Quality Various Types Nickel Chrome Heating Wire Resistance Wire, Micc professional K Type N Type Mineral Insulated Thermocouple Cable Mi Cable and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Optical Fiber, Cable & Wire Electric Wire & Cable China High Temp K Type Glass Fiber Braid Thermocouple Extension Wire

China High Temp K Type Glass Fiber Braid Thermocouple Extension Wire

Get Latest Price
Min. Order / Reference FOB Price
10 Meter US $1.00/ Meter
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Micc
Type: Bare
Conductor Type: Stranded
Conductor Material: Copper
RTD Extension wire Type RTD-PVC /PVC -3x7/0.15
1. Conductors: Nickel plated copper
2. Insulation: Extruded PVC
3. Overall jacket: Extruded PVC
4. Good quality
RTD Extension wire Type RTD-PVC /PVC -3x7/0.15
1, SUBJECT
This specification covers the requirements for PVC insulated, PVC sheathed RTD extension cable, 3x26AWG, strand wire, twisted construction.
Thermocouple wire
Thermocouple extension wire
1. Conductors: Positive Chrome
Negative Alumel
2. Insulation: Extruded PTFE
3. Overall Jacket: PTFE
Thermocouple wire
1, SUBJECT
This specification covers the requirements for PTFE insulated and PTFE sheathed thermocouple extension cable, type KX, 2x7/0.2mm, strand wire, standard tolerance and color code.
2, TECHNICAL FEATURES
A. Conductors:
Stranded thermocouple extension wire
Conductor Size (AWG)
No. Of Strands & Gauge
24
7/0.2mm
B. Insulation:
Extruded PTFE ( 260º C )
Nominal Insulation Thickness: 0.31mm ± 0.2
Color code
Positive
Color
Chromel
Yellow
Negative
Color
Alumel
Red
C. Assembly:
Two conductors (positive and negative) parallel construction.
D. Overall Jacket:
Extruded PTFE ( 260º C )
Nominal Sheath Thickness: 0.28mm ± 0.2
Color code:
Yellow
3, DIMENSIONS AND TOLERANCES
Dimensions / tolerances (mm)
1.43± 0.25x2.38 ± 0.25
4, CALIBRATION TOLERANCE
Temperature range
Standard tolerance*
Special tolerance*
0º To 260º C
± 2, 2° C or 0.75%
± 1, 1° C or 0, 4%
*whichever is greater
Thermocouple type available: KX, JX, TX, EX, NX, RX, SX and other compensating cable like KCA, KCB and so on