Description:
In AAC line,Autoclave mainly used for steaming AAC block.
after steamed,Blocks will be hardness.
Autoclave working hours:
Air suction from autoclave: 0.5h(0~-0.06MPa)
Raising steam pressure: 1.5h(-0.06~1.3MPa)
Maintaining the pressure: 8h(1.3MPa)
Discharging steam: 1.5h(1.3~0MPa)
Total:12hours
Remark:Maintaing the pressure is not fixed.customer can adjust it based on self stations.
Autoclave specifications:
NoInner diamater(m)Length(m)Design pressure(MPa)Working pressure(MPa)1φ2.021,22.5,26.5(27),31(31.5)1.41.32φ2.526.5,31(32)1.61.53φ2.6826,32,381.61.54φ2.7526,32,,381.61.55φ2.8526,321.61.5
Working process:
A) After welding the door, it must be proceed annealing heat treatment.
B) Polish toothed cutter of flange of autoclave body, and carry out magnetic particle testing.
C) Use double scale container board, and ensure the longitudinal joint of each section.
D) Carry out the physical and chemical test (stretch, impact), ensure its strength.
E) Welds are 100% X-ray detection, then carry out hydraulic test of 2.1MPa after passing. The whole process is complete inspected by CSEI factory inspection, and leave factory after stamp and signature.
Safety interlock protection:
A) Hand speed reducer installs mechanical interlocking, and we don't move when there's pressure in kettle.
B) Equip with manual limited safety interlocking device, stuck kettle manually, and when it opens, then we can open the door.
C) Equip with electric limited safety interlocking device, use cooperatively with manual limit, and connect with electric cabinet, rotating electrical ark with pressure and sound-light alarm.