Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Fire Alarm Control Panel, FM200 System, Smoke Detector, Manual Call Point, Heat Detector, ..
Establishment:
2012
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa
OEM/ODM Service
Sample Available

Fire Alarm System, Control System, Fire Alarm manufacturer / supplier in China, offering Wired Addressable Control Panel Fire Alarm System, 2-Wire Conventional Fire Alarm Control Panel for Hotel Use, Asenware Manufacturer Addressable Fire Alarm Control Panel for Office Building and so on.

1
    YRS
General Supplier

China Home Fire Security Alarm Host Panel

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $525.00/ Piece
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Type: Smoke Alarm
Signal Transmission: Wired Alarm
Working Mode: Active
Home Fire Security Alarm Host Panel
(Max support 20PCS detectors/Zone. )
Function Introductions:
1. R&D based on EN54 part 2 & 4 standard.
2. Modularized design with flexible extendable capacity.
3. Two-level control mode by a lock
4.27VDC power supply output.
5. FIRE PROTECTION, FIRE ROUTING and FAULT signal output, the output can be configured to dry relay type or wet sources type.
6.2 channel general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. RESET button to reset the panel.
10. SILENCE button to stop BUZZER and SOUNDERS.
11. EVACUATE button to start a manual fire alarm immediately.
12. TEST button to test all LEDs orderly.
13. Low-level battery automatic switch & protection function.
14. Optional GSM module is available for fire alarm by SMS.
Asenware, professional fire alarm solution provider.

ITEM1Zone panel2Zone panel4-8 Zone panel12-32 Zone panelModel No.AW-CFP2166-01AW-CFP2166-02AW-CFP2166-04-8AW-CFP2166-12-32Power specification
Mains supply voltage110VAC or 240VACInternal power supply27.2VDCTotal output current limited500mA @ 240VAC500mA @ 240VAC3A @ 240VAC3A @ 240VACMain supply monitor for faultYesBattery protection for low voltageYesBatteries (default configuration)12V2AH*2Detector circuit specification
Number of circuit124-164-32Line fault monitor for open circuitYesLine fault monitor for short circuitYesLine fault monitor for detector removalYes, if End of Line Monitor Unit fitted in place of End of Line ResistorEnd of Line device6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)Detector continuity diodesSilicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault)Call point resistor value470 to 680 Ω, 0.225 or 0.5 wattMaximum number of smoke/heat detectors per zone20 (based on a total detector current of 2mA, each detector consuming 100μA).Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts.Maximum number of manual call points per zoneNo limitSounder circuit specification
Number of general circuits2End of line resistor value6.8k Ω,5% tolerance, 0.25W (colour code-blue,grey,red,gold)Line fault monitor for open circuitYesLine fault monitor for short circuitYesOutputs fused AT400mAMaximum number of bells @ 20mA of each sounder output20Fuses
Battery fuse1.5A F 20mmSounder outputs500mA F 20mmFire and fault output
Output typeNC and NO relayMaximum current100mAConnection block
Largest acceptable conductor size2.5mm2Smallest acceptable conductor size0.75mm2Size and weight

Dimensions(mm)272*200*70mm320*231*90mm395X502X124362X565X124Weight (without batteries)4kg5kg7kg8kgWeight (with batteries)5.8kg6.8kg9.6kg12.5kg