Hospital Equipment ConTEC Multi-Parameter Patient Monitor CE/FDA Approved
Model:CMS90000 Brand:CONTEC
Introduction:
This hospital equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP.It integrates parameter measuring module, display and recorder in one device to form a high cost-performance, high safety and low power consumption device.
Standard parameter:ECG,SPO2,RESP,TEMP,NIBP,PULSE RATE
Optional Parameter:ETCO2,CO,IBP,Thermal Printer
Patient Range:Adult.Pediatic,Neonatal
Features
- 12.1" Color TFT Screen, waveform up to 8 channels
- Light and portable with build-in rechargeable battery
- UP to 10 kinds of monitor parameters
- Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
- 72 hours storage and review of trend grams and tables, 40 second review of olographic wavefo RMS.
- All-round monitor of adult, pediatric and neonatal.
- Electrosurgical unit and defibrillation protected
- Standard parameters:ECG, NIBP, SpO2, Respiration, Temperature, Pulse rate
- Option parameters:EtCO2, CO, IBP, Thermal Printer
ECG
- 5-lead or 3-lead selectable
- Input:5-lead:RA;LA;RL;LL;V or R;L;N;F;C
- Lead selection:I;II;III;AvR;AvL;AvF;Vx;CAL
- Gain selection:12.5mm/s, 25mm/s, 50mm/s
- Accuracy:± 1bpm or ± 1%, whichever is greater
- Protection:Withstand 4000VAC/50Hz voltage in isolation against electrosurgical and defibrillation
- Calibration signal:1mV± 5%
- Operation modes:Diagnostic, Monitor, Surgery
- Alarm range:Adult:15-300bpm
- Pediatric/Neonatal:15-350bpm
- Alarm range:-2.0mV~2.0mV
- S-T detection:YES, Arrhythmia analysis:YES
- Alarm:YES, audible and visual alarm, alarm events recallable
NIBP
- Method:Oscillometry
- Operation modes:Manual/Automatic/STAT
- Measurement unit:MmHg/KPa selectable
- Measurement types:Systolic, Diastolic, Mean
- Measurement range:Adult:10-270mmHg
- Over-pressure protection:YES
- Resolution:1mmHg
- Accuracy:Mean error and standard deviation per ANSI/AAMI SP-10
- Alarm:Systolic, Diastolic, Mean
SpO2
- Measurement range:0-100%
- Accuracy:± 2digit (70~100%);
- 0~69% unspecified
- Alarm range:0-100%
Respiration
- Method:RA-LL impedance
- Pediatric/Neonatal:6-150rpm
- Alarm range:Adult:6-120rpm
- Pediatric/Neonatal:6-150rpm
- Apnea alarm:YES
Temperature
- Resolution:0.1
- Channel:Dual-channel
- Alarm range:0-50
Option:
EtCO2
- Measurement Mode:Side-stream or mainstream
- Measurement range:EtCO2:0-99mmHg
- Accuracy:CO2 concentration
- Apnea alarm:YES
IBP
- Channel:2 channels
- Pressure transducer:Sensitivity:5( mV/V/mmHg)
- Transducer sites:ART, PA, CVP, RAP, LAP, ICP
- Alarm range:-10~300mmHg
Standard six parametersECG,SPO2,RESP,TEMP,NIBP,PULSE RATEOptionalETCO2,CO,IBP,Thermal PrinterScreen size12.1 inchSize310*140*263mmNet Weight3.8kgAccessories1) Adult SpO2 probe(5-pin)2) Adult NIBP cuff3) Extending tube for blood pressure4) ECG lead5) ECG electrode6) Temperature probe7) Power cord8) Thermal recording paper(optional)9) User Manual