Portable Pulse Oximeter, Pulse Oximeter, Oximeter manufacturer / supplier in China, offering Portable Pulse Oximeter with (Perfusion Index) Pi Display, China Manufacturer 12.1" Portable Multi-Parameter Patient Monitor, Contec Ha3100 Blood Hematology Analyzer and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $150.00/ Piece |
Local Area: | Qinhuangdao, Hebei, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T |
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
---|---|
Type: | Patient/Fetal/Maternal Monitor |
Certification: | CE, MSDS, ISO13485 |
Introduction oF CMS5000-Vital Signs Monitor
Hospital Equipment Vital Signs Patient Monitor/ Bedside Blood Pressure Monitor CMS5000 adopts Oscillometry technology, also called Oscillography technology for NIBP measuring(Monitoring), and adopts Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure (SYS), Diastolic Pressure (DIA), Mean Pressure (MAP), SpO2 and Pulse rate (PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.
Measurement methodOscillometryMeasurement modeManual/auto/continuousAuto measurement intervalAdjustable from 1 to 255 minutes.Resolution1mmHg.Accuracy:Maximum Mean deviation≤ ± 5mmHg, Maximum Standard deviation≤ 8mmHg.Overpressure protectionDouble protection for software and hardware.Range:Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHgPediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHgNeonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHgUpper and lower limit of alarmAdult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHgPediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHgNeonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
SpO2 MeasuringRange:35%~100% (Resolution: 1%)Accuracy: ± 2% in stage of 70%-100%, and unspecified in stage of less than 70%.Pulse Rate MeasuringRange: 30bpm~250bpm(Resolution: 1bpm)Accuracy: ± 2bpm or ± 2%, whichever is greater.Measurement Performance in Weak Filling ConditionSpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ± 4%; The Pulse rate error is ± 2bpm or ± 2%, whichever is greater.Resistance to surrounding lightThe deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ± 1%.