Business Type:
Trading Company
Business Range:
Medical dressing, Medical disposable, Medical equipment, Laboratory disposable, Patient care supplies
Establishment:
2016
R&D Capacity:
OEM, ODM, Others
Terms of Payment:
LC, T/T, D/P, Paypal, Western Union
Main Markets:
Mid East, Africa, Southeast Asia
OEM/ODM Service
Sample Available

LUCKmed is one of the main global providers of medical devices and solutions. Firmly committed to our mission of Concentrate on professional medical services, we are dedicated to innovation in the fie...

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Nursing Equipment China Hospital Infant Radiant Warmer Baby Warmer

China Hospital Infant Radiant Warmer Baby Warmer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $5800.00/ Piece
Local Area: Qingdao, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, Paypal, Western Union
Customized: Customized
Certification: CE, ISO13485
Scale: Medium
Hospital Infant Radiant Warmer Baby Warmer

Infant Radiant Warmer DS-BN200

Three control modes: Pre-warm mode control, manual mode control and baby mode control by micro-computer;

The information can be stored, consulted and indicated by the LCD display screen;

Failure alarm indication;

The angle of heater head is adjustable horizontally and radiant light is always focusing on mattress from each angle;

Inclination of the bassinet is adjustable; The panels around bassinet can be turned outward;

Silicon mattress is heatable and temperature is controllable;

With LED phototherapy function;

APGAR timer;

Vertical height adjustment (VHA) stand;

Disposable skin temperature sensor is optional.
Specifications

Power requirementAC220V-230V/50Hz or AC110-120V/50-60Hz, 900VAMode of controlPre-warm mode, manual mode and baby mode are controlled by micro-computerBaby mode temperature control range34.5-37.5°CAccuracy of temperature control≤0.5°CAccuracy of skin temperature sensor± 0.2°CTemperature uniformity of mattress≤ 2°CMattress heating control range25-38°CAccuracy of mattress temperature display± 0.7°CAngle of warmer module±60° rotatable , radiant light is always focusing
on mattress from each angleInclination of bassinetThe Max. angle on trendelenburg is 15° , on reverse trendelenburg is 20°APGAR timeraudible and visible alarm when the device runs to 50" - l', 4' 50" - 5' , 9' 50" - 10'Failure alarmover temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.Max. bilirubin radiation on the mattress effective range≥ 1mW/cm2Average value general bilirubin radiation of on the mattress effective range≥ 0.8mW/cm2Bilirubin uniformity of radiating on the mattress effective range> 0.4