Our company is a manufacturer and exporter of medical and industrial products. With high jumping-off point, our company was formed by a group of experts and senior managers from various companies with...
Min. Order / Reference FOB Price | |
---|---|
1000 Piece | US $10.34/ Piece |
Local Area: | Jian, Jiangxi, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, Paypal, Western Union |
Type: | Surgical Supplies Materials |
---|---|
Material: | Plastic |
Ethylene Oxide Sterilization: | Ethylene Oxide Sterilization |
Hospital Low Flux and High Flux Blood Hemodialysis Dialyzer
1.Technical Specifications:
Performance parameters and specifications
Parameter
Qb/Qd(ml/min)
SM120L
SM140L
SM160L
SM180L
SM200L
Effective Surface Area(m2)
1.2
1.4
1.6
1.8
2.0
KOA Urea(mL/min)
537.5
575.3
603.5
651.8
689
Urea
200/500
174
177
179
182
184
300/500
255
229
231
235
238
400/500
261
266
269
273
276
Creatinine
200/500
158
161
163
165
167
300/500
210
214
217
219
222
400/500
225
229
232
235
238
Phosphate
200/500
147
155
159
163
165
300/500
202
213
218
224
226
400/500
235
243
249
255
258
Vitamin B12
200/500
98
105
112
118
124
300/500
104
112
120
126
133
400/500
120
130
139
146
154
KUF(mL/hr/mmHg)
12
14
16
18
20
Performance parameters and specifications
Parameter
Qb/Qd(ml/min)
SM120H
SM140H
SM160H
SM180H
SM200H
Effective Surface Area(m2)
1.2
1.4
1.6
1.8
2.0
KOA Urea(mL/min)
873.3
954.9
1064.9
1232.9
1367
Urea
200/500
191
193
195
197
198
300/500
255
260
267
275
280
400/500
300
310
320
330
340
Creatinine
200/500
180
182
185
190
195
300/500
232
241
250
260
270
400/500
270
280
295
305
317
Phosphate
200/500
175
178
181
185
190
300/500
215
225
235
250
262
400/500
242
260
280
295
305
Vitamin B12
200/500
138
146
155
165
175
300/500
159
167
175
195
208
400/500
170
180
190
200
212
KUF(mL/hr/mmHg)
50
55
60
65
70
Sieving Coefficient
Inulin 0.9
Myoglobin ≥0.5
Albumin ≤0.01
To function more like the human kidney, we built thousands of fibers into each dialyzer where every fiber acts as a nephron (human kidney element). Its advanced pore-spinning technology creates more homogenous pore sizes to optimize sieving properties,also its uniform pore size results in improved removal of uremic toxins and low-molecular-weight proteins, with limited loss of important proteins such as album in.
CNMEDITECH advances the dialyzer design in terms of composition,removal performance and results. We start with lighter, polypropylene housing and headers, which do not contain BPA. The inner design-featuring an ultra-smooth polypropylene cut surface and finely finished inner lumen of hollow fibers ensures smooth blood flow and minimizes potential blood cell damage.
Improved header shape with redesigned,permanent caps reduces channeling at the blood side while eliminating possibility of unexpected removal or reuse.
Ultra-smooth polyurethane cut surface on dialyzer minimizes risk of blood cell damage during hemodialysis.
2.Hospital Low Flux and High Flux Blood Hemodialysis Dialyzer detailed picture: