Surgical Face Mask, Disposable Face Mask, Disposable 3-Ply Face Mask manufacturer / supplier in China, offering Medical Non-Woven Surgical Face Mask Disposable with Tie-on Bfe>99%, Medical Protection Face Shield, Cheapest Gun Shape Baby Non-Contact Infrared Forehead Thermometer and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Pieces | US $440.00/ Pieces |
Local Area: | Chengdu, Sichuan, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Brand: | Yushengda |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Type: | Patient/Fetal/Maternal Monitor |
Certification: | CE, FDA, EEC, MSDS, ISO13485 |
YSD16L-Vet Veterinary Portable Patient Monitor
Main Features
★ 6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR.
★ 12.1"high resolution color TFT LCD display.
★ Multilanguage operation softwares,Chinese,English,Turkey,Spain,Russian,French
★ Multichannel display
★ Big font interface
★ ST and arrhythmia analysis
★ Drug dose calculation and titration table
★ OxyCRG dynamic view display
★ Respiration monitoring with apnea alarms
★ Alarm review, arrhythmia review
★ Patient info. Input
★ Antidefibrillation design
★ NIBP over pressure protection
★ Plugin rechargeable battery, AC/DC available.
★ Real time S-T segment analysis, pace-maker detection.
★ Indication of Incorrect manipulation and malfunction analysis.
★ Patient info input management function
★ Multi-lead ECG waveforms display in phase.
★ Large volume of tabular and graphic trends information storage and easy to recall.
★ Capture dynamic waveforms.
★ Efficient resistance to interference of defibrillator and HF knife.
★ UP to 3 hours working capacity of built-in rechargeable battery.
★ Unique accessory management cabinet.
★ Networking capacity.
★ Option: Nellcor SpO2, EtCO 2, IBP, Thermal Recorder
Technical Specifications
ECG
Lead Mode5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)Lead selectionI, II, III, avR, avL, avF, VWavef orm2 chLead mode3 Leads ( R, L, F or RA, LA, LL)Lead selectionI, II, III,Wave form1 chGain2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, autoHR and Alarm RangeAdult 15 ~ 300 bpmNeo/Ped 15 ~ 350 bpmAccuracy±1% or±1bpm, which is greaterResolution1 bpmSensitivity> 200 (uVp-p)Differential Input Impedance> 5 MΩCMRRMonitor: > 105 dBOperation: > 105 dBDiagnosis: > 85 dBElectrode offset potential±300mVLeakage Current< 10 uAbaseline Recovery< 3 S After Defi.ECG Signal Range±8 m V ( Vp-p )BandwidthSurgery: 1 ~ 20 HzMonitor: 0.5 ~ 40 HzDiagnostic: 0.05 ~ 130 HzCalibration Signal1 (mVp-p)Accuracy5%ST Segment Monitoring RangeMeasure and Alarm: -2.0 ~ +2.0 mVARR DetectingTypeASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, RONT, VT>2,BRADY, MISSED BEATS, PNP, PNC, Alarm Available, Review Available
Respiration
MethodImpedance between R-F(RA-LL)Differential Input Impedance> 2.5 MΩMeasuring Impedance Range0.3~3 Ωbase line Impedance Range200~4 KΩBandwidth0.1~2.5HzResp. RateMeasuring and Alarm Range Adult: 0 ~ 120 Brpm Neo/Ped: 0 ~ 150 Brpm Resolution: 1 Brpm Accuracy: ±2 BrpmApnea Alarm10 ~ 40 S
NIBP
MethodOscillometricModeManual, Auto, STATMeasuring Interval in AUTO Mode 1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)Measuring Period in STAT Mode5 MinPulse Rate Range40 ~ 240 bpmAlarm TypeSYS, DIA, MEANMeasuring and alarm rangeAdult ModeSYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg Pediatric ModeSYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg Neonatal ModeSYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHgResolution1mmHgAccuracyMaximum Mean error±5mmHgMaximum Standard deviation±8mmHgOverpressure ProtectionAdult Mode297±3 mmHgPediatric Mode240±3 mmHgNeonatal Mode147±3 mmHg
SpO2
Measuring Range0 ~ 100 %Alarm Range0 ~ 100 %Resolution1 %Accuracy70% ~ 100% 2 % 0% ~ 69% unspecifiedActualization intervalabout1 Sec.Alarm Delay10 Sec.Pulse RateMeasuring and Alarm Range20~300 bpmResolution1bpmAccuracy±3bpm
TEMP
Channel 2Measuring and Alarm Range0 ~ 50 ºCResolution0.1 ºCAccuracy±0.2 ºCActualization intervalabout1 Sec.Average Time Constant< 10 Sec.
IBP
LabelART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and alarm rangeART 0 ~ 300 mmHg PA -6 ~ 120 mmHg CVP/RAP/LAP/ICP-10 ~ 40 mmHg P1 / P2-10 ~ 300 mmHgPress SensorSensitivity5uV/V/mmHg Impedance300-3000ΩResolution1 mmHgAccuracy±2% or 1mmHg which is greaterActualization intervalabout 1 secretary