Tan Delta Tester, Capacitance & Tan-Delta Tester, Capacitance & Dissipation Factor Test Set manufacturer / supplier in China, offering Automatic Electronic Different Frequency Anti-Interference Capacitance Power Transformer Capacitance Measuring & Dissipation Tester, Ydq Gas Type 1.5kVA 3kVA 5kVA 10kVA 15 kVA 20kVA 25kVA High Voltage Pneumatic Electricity Test Set Voltage Tester, Htxz Frequency Conversion/Power Frequency Cable Resonance Test System and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Set | US $2880.00/ Set |
Local Area: | Wuhan, Hubei, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, WesternUnion |
Transport Package: | Wooden Case or Carton |
---|---|
Specification: | see details |
Trademark: | HV TEST |
1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself; the actuation time is less than 15ms.
3. Overcorrect protection: it is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 15ms.
4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
5. As a result of high and low voltage closed-loop negative feedbacks control circuit, the output without capacitive rise effect.
6. High-voltage control part adopts innovative light control HV switching unit, control is accurate, safe and reliable;
7. With color man-machine interface touch control plus controls modular software operating system, precise and intuitive
8. Multi-purpose, can simultaneously measure tested objects capacitance, insulation resistance, leakage current, and AC withstand voltage test
Model Rated Voltage Load CapacityFuseReference WeightVLF-30 (30KV)30kV/20mA
(Peak)0.1Hz,≤1.1µF5AController: 4kg
Booster:25kg0.05Hz,≤2.2µF0.02Hz,≤5.5µFVLF-50 (50KV)50kV/30mA
(Peak)0.1Hz,≤1.1µF15AController:4kg
Booster: 50kg0.05Hz,≤2.2µF0.02Hz,≤5.5µFVLF-80 (80KV)80kV/30mA
(Peak)0.1Hz,≤0.5µF20AController:4kg
Booster 1(30kV):25kg
Booster 2(50kV):50kg0.05Hz,≤1µF0.02Hz,≤2.5µF
Output rated voltageSee table 1Output frequency0.1Hz,0.05Hz,0.02HzLoad capacitySee table 10.1Hz max 1.1 μf0.05 Hz max 2.2 μf0.02 Hz max 5.5 μfMeasurement accuracy2.5 %Positive and negative voltage peak errors≤2.5%Voltage wave form distortion≤3%Insulation resistance measurement error≤2.5%Leakage current measurement error≤2.5%PowerAC 50 Hz,220V ±5%Power FuseSee table 1