Sectionalizer, Auto Circuit Breaker, Distribution manufacturer / supplier in China, offering 15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation, Pasgt Tactical M88 U. S. Army Steel Replica Anti-Riot Helmet Full Head Coverage with Adjustable Chin Strap for Personal Safety of Airsoft Hunting Paint Ball Bb, Od8mm Stainless Steel Bowfishing Line Guiding Rod with Ceramic Eyelet Accessory Fit Reel Seat Mount for Fishing Bow Fishing Slingshot and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Electrical Control System China Ied′s 69kv 3 Phases Transformer Differential Protction

China Ied′s 69kv 3 Phases Transformer Differential Protction

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $10000.00/ Piece
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Task: Program
Structure: Combination
Mathematical Model: Linear

IED´S TRANSFORMER DIFFERENTIAL RELAY 69KV TRANSFORMER DIFFERENTIAL TREALY QUANTITY3yesMOUNTING INCLUDING WHERe CNEL EP INDICATEyesDIFFERENTIAL87 TYESOVERCURRENT ( 1 and 2 WINDINGS ))50/51YES50N/51NYES5OG / 51GYESNEGATIVE SEQUENCE46YESTEMPERATURE49YESINRUSH YESFAULT FUSEIFYESALARM ANNUNCIATORSPROGRAMMABLE LEDSYESINTERNAL COMPENSATIONIFYESRESTRICTION OF HARMONICS2.5.3YESSLOP (ramps)3 MINIMUMYES I dif.Differential currentYES(I) bar.Restriciion currentsYESICurrent primary and secondary dedavanoYESCURRENTIYESVOLTAGEVYESPOWER FACTORFPYESPOWERSACTIVE, REACTIVE AND APPARENTYES OPEN (IN A PHYSICAL WAY) YESCLOSE (IN A PHYSICAL WAY) YESTRIGGERTRIPOLARYES OSCILOGRAFIASPre fails - post failureYESDATE YESTIME YESFAULT CURRENT SEQUENCE +, - AND 0 YESFAULT SIGNALLINGUSE OF LEDYES DIGITAL INPUTS6 MINIMUM7DIGITAL OUTPUTS6 MINIMUM7CURRENT NOMINAL SECONDARY1-5 AMPYESADJUST TAPLESSER or equal 0.5 InYESSTANDARDSANSI-IECYESPOWER SUPPLY 180-240 VDCYESPOWER 280-240 VacYESPULSES OF VOLTAGEDIGITAL INPUT, DIGITAL OUTPUTYES 10 YEARSMINIMUMYESTERMINAL TEST - SHORTCIRCUITABLE TERMINAL TEST - SHORTCIRCUITABLESHORTCIRCUITABLE TERMINALS AND TESTS SHOULD COME WITH THE INSTALLATION MANUAL IN SPANISH, THE TERMINAL BOARD MUST BE ABLE TO WITHSTAND VALUE OF INJECTION OF SEConDARY CURRENT MINIMUM 100 A. IS ACCEPTED THAT THE TWO TERMINALS COME IN A SINGLE ELEMENT, IN CASE THAT THE PURCHASE INCLUDE BOARD POSITION, TERMINALS MUST BE ALREADY INSTALLED AND READY TO OPERATE. THE PROTECTIONS OF CNEL EP GROUP WILL CARRY OUT INJECTION TESTING ALTOGETHER WITH A TECHNICIAN OF MANUFACTURES OR SERVICEMAN OF THE OFFEROR AND VERIFY THE OPERATION THEREOF IN ConJUNCTION WITH THE PROTECTION RELAY.YES TRAINING CERTIFIED IN SPANISH LANGUAGE WITH CERTIFIED INSTRUCTOR FROM FACTORY1 training 5 days, after that the OFFEROR is required to give training for a year until they are solvent doubts IED´s. this under prior coordination with the administrator of the contract of CNEL EP, these skills will be two-day minimum 5 times A year, to failure to comply with this shall present its poor compliance for future contracts offered by CNEL EP.YES2 SUBJECT PROTECTIONS SETTINGS, THE PERSON WHO WILL GIVE THE TRAINING MUST BE PROTECTIONS ENG. AND SHOULD BE IN FULL KNOWLEDGE OF THE SUBJECT, ABLE TO RESOLVE ALL QUESTIONS SUBMITTED AT THAT TIME.YES3. COMMUNICATION TO THE ConTRACT ADMINISTRATOR YES4. IEC 61850, WANT TO MAKE AN EXAMPLE
TWO IED´s this should be demonstrated and
IN FULL ACCEPTANCE OF THE GROUP
ASSISTANT TO THE TRAINING.YES5. EVIDENCE OF CURRENT INJECTION YES6. INSTALLATION ON THE SAME FIELD, IF IT
REQUESTED SEVERAL INSTALL ONE AS EXAMPLE, PART OF THE TRAINING.YESLICENSEFREE (N NUMBER OF USERS)YESLOCAL TECHNICAL SUPPORTADDRESSES, PHONES, RESPONSIBLE
WITH STAFF TO SUPPORT TECHNICIAN, document NOTARIZED SIGNATUREYESMANUALSpanishEnglishAMBIENT TEMPERATUREMORE THAN 40 DEGREES, LESS THAN THAN 10YES CERTIFICATE OF SOLE REPRESENTATIVE AUTHORIZED BRAND IN PROTECTION RELAYSOKYES CERTIFICATE KEMA IEC 61850-6, 7-1, 7-2, 7-3, 7-4 and 8-1OKYESCERTIFICATES STANDARD ISO 9001OKYESCERTIFIED NOTARIZED THAT ConSISTS WITH TECHNICAL
WITHIN THE EQUATOR TO HAVE SOLUTIONS HOME-
DIATASOKYES PORTS TYPEDEscriptION FRONTRJ-45, RS 485FIELD CONFIGURATIONRS2322 PORTS, REARETHERNETNETWORK ConFIGURATION WITH REDUNDANCY DOUBLE OR RING, SCADA INTEGRATION CONFIGURATIONYES2 PORTS, REARFIBER OPTICSNETWORK ConFIGURATION WITH REDUNDANCY DOUBLE OR RING, SCADA INTEGRATION CONFIGURATIONYES1 PORT DB9-IRIG-BTIME SYNCHRONIZATIONYES1 PORT RS-485THE SCADA INTEGRATIONYESCALIBRATION AND TESTINGOK THE ConTRACTOR MUST GIVE IT YESSETTINGSOKCNEL EP ESMYESPROTOCOLSETHERNET YESMODBUS/TCP, DNP3/LAN/WAN, FTP, TELNET, PING, IEC 61850YESSERIALYESDNP3, MODBUS RTU, YES