Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Cable, Power Cable, Service Drop Cable, Wire, Overhead Conductor
Establishment:
2001
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
South America, Africa, Others
OEM/ODM Service
Sample Available

Electrical Wire, Flexible Cable, Flat Wire manufacturer / supplier in China, offering Flexible Solid Stranded Copper Aluminium PVC Insulated Electric Wire Cable, Aerial Bundle Cable Four Core 70mm2, All Aluminium Alloy Conductor AAAC for Overhead and so on.

1
    YRS
General Supplier

China LV Cable Al Copper Conductor Multicore

Get Latest Price
Min. Order / Reference FOB Price
1000 Meter US $0.01/ Meter
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Brand: Yifang
Type: Insulated
Conductor Type: Stranded
Application: Overhead
Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage

ConstructionConductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.

Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

Outer Sheath

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.